CoChat

Changes in the perception of inspiratory resistive loads during partial curarization.

Open access
Campbell, E J, Gandevia, S C, Killian, K J, Mahutte, C K, Rigg, J R · 1980 · The Journal of Physiology
Cited by 103

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

1. The ability of normal subjects to estimate the magnitude of resistive loads and to detect resistive loads was determined using standard psychophysical techniques. The experiments were repeated during maintained partial neuromuscular blockade with D‐tubocurarine. 2. During curarization the ability to detect the presence of a small inspiratory resistive load was not significantly impaired. This finding is consistent with the view that changes in the usual breath‐by‐breath relation between pressure and flow mediate detection. 3. The size of resistive loads was over‐estimated during partial curarization. Subjects thus placed more reliance on sensing the increased motor command required during curarization than on alternative peripheral signals related to pressure, flow or resistance. 4. The exponent for the power function relating the perceived magnitude of a resistive load to its actual size (Stevens, 1957) was reduced during partial neuromuscular blockade. 5. These results suggest that detection of resistive loads depends upon sensing apparent information arising from an unexpected pressure‐flow disturbance but that estimation of the size of an added load depends, in part, on sensing the outgoing motor command.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1980.sp013496

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 103

Metadata

Authors
Campbell, E. J., Gandevia, S. C., Killian, K. J., Mahutte, C. K., & Rigg, J. R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1980-12
Volume
309
Issue
1
Pages
93-100
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2082385207
Cited by
103
References
1
FWCI
1.61
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.