Changes in the perception of inspiratory resistive loads during partial curarization.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. The ability of normal subjects to estimate the magnitude of resistive loads and to detect resistive loads was determined using standard psychophysical techniques. The experiments were repeated during maintained partial neuromuscular blockade with D‐tubocurarine. 2. During curarization the ability to detect the presence of a small inspiratory resistive load was not significantly impaired. This finding is consistent with the view that changes in the usual breath‐by‐breath relation between pressure and flow mediate detection. 3. The size of resistive loads was over‐estimated during partial curarization. Subjects thus placed more reliance on sensing the increased motor command required during curarization than on alternative peripheral signals related to pressure, flow or resistance. 4. The exponent for the power function relating the perceived magnitude of a resistive load to its actual size (Stevens, 1957) was reduced during partial neuromuscular blockade. 5. These results suggest that detection of resistive loads depends upon sensing apparent information arising from an unexpected pressure‐flow disturbance but that estimation of the size of an added load depends, in part, on sensing the outgoing motor command.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Vallbo, Å. B. (1971) · The Journal of Physiology · doi:10.1113/jphysiol.1971.sp009625 · Cited by 312
Cited by
Parshall, M. B., Schwartzstein, R. M., Adams, L., Banzett, R. B., Manning, H. L., Bourbeau, J., Calverley, P. M., Gift, A. G., Harver, A., Lareau, S. C., et al. (2012) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.201111-2042st · Cited by 1,844
Neurobiology of muscle fatigue
Enoka, R. M., & Stuart, D. G. (1992) · Journal of Applied Physiology · doi:10.1152/jappl.1992.72.5.1631 · Cited by 1,429
Dyspnea: Mechanisms, Assessment, and Management: A Consensus Statement
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.ats898 · Cited by 1,052
Dyspnea Mechanisms, Assessment and Management: A Consensus Statement
Editorial, A. (2005) · PULMONOLOGIYA · doi:10.18093/0869-0189-2005-0-2-9-36 · Cited by 808
Pathophysiology of Dyspnea in Chronic Obstructive Pulmonary Disease: A Roundtable
O'Donnell, D. E., Banzett, R. B., Carrieri-Kohlman, V., Casaburi, R., Davenport, P. W., Gandevia, S. C., Gelb, A. F., Mahler, D. A., & Webb, K. A. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200611-159cc · Cited by 380
Self-citation
Metadata
- Authors
- Campbell, E. J., Gandevia, S. C., Killian, K. J., Mahutte, C. K., & Rigg, J. R.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1980-12
- Volume
- 309
- Issue
- 1
- Pages
- 93-100
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2082385207
- Cited by
- 103
- References
- 1
- FWCI
- 1.61
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.