Effect of ions on retinal rods from Bufo marinus.
Open accessThe DOI matches its Crossref record.
Abstract
The effect of ions on the light‐sensitive current of isolated retinal rods from the toad Bufo marinus was studied by sucking the inner segment into a tightly fitting pipette. The outer segment projected into flowing solution whose composition could be changed rapidly. Reducing the external Na concentration, [Na]o, round the outer segment caused rapid and reversible reductions in the light‐sensitive current. With the outer segment in the pipette, reductions of [Na]o round the inner segment had little effect on the light‐sensitive current. The current about 15 s after a change in [Na]o was approximately proportional to [Na]2o. The current decreased in elevated external Ca concentration, [Ca]o, and increased in reduced [Ca]o. Between 10 and 0.5 mM‐external Ca the current 15 s after a change was approximately inversely proportional to [Ca]o. Reducing [Ca]o from 1 mM to 1 microM or less transiently increased the current by about 15‐fold. After a change in [Na]o or [Ca]o the current did not approach its final value monotonically but with a characteristic overshoot or underswing, followed by a slow relaxation of current which may reflect the time course of change in internal Na. Reducing [Na]o from 110 to 70 mM or less prolonged the response to a flash; very long responses were observed in solutions containing Li rather than Na and also in rods that had been returned to Ringer solution after exposure to low Ca. All these effects might be explained if Ca extrusion in exchange for Na determines the reactivation of current after a flash. The rod current was not changed if the ratio [Na]No/[Ca]o was held constant, N being about 2.5. Between 5 mM and 10 microM‐Ca the change in peak current produced by absorption of a single quantum was roughly proportional to the dark current. Responses in the absence of external Na were not normally seen if the solution contained 0.1 mM‐Ca or more. Responses of normal polarity were regularly observed in 0 Na, 0 Ca EGTA solutions containing 1.6 mM‐Mg. Removal of Mg from such solutions gave inverted responses. Other conditions which promote responses of normal and inverted polarity in Na‐free solutions are described briefly. We conclude that Li, Ca, Mg and perhaps K can pass through the light‐sensitive channel. The above results suggest that external Na has two distinct effects: (1) it provides ions to carry inward current, and (2) it keeps the light‐sensitive conductance open by maintaining the internal Ca concentration, [Ca]i, at a low level.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Sodium/Calcium Exchange: Its Physiological Implications
Blaustein, M. P., & Lederer, W. J. (1999) · Physiological Reviews · doi:10.1152/physrev.1999.79.3.763 · Cited by 1,736
Induction by cyclic GMP of cationic conductance in plasma membrane of retinal rod outer segment
Fesenko, E. E., Kolesnikov, S. S., & Lyubarsky, A. L. (1985) · Nature · doi:10.1038/313310a0 · Cited by 1,211
Calcium and light adaptation in retinal rods and cones
Nakatani, K., & Yau, K.-W. (1988) · Nature · doi:10.1038/334069a0 · Cited by 386
Self-citationLight-induced reduction of cytoplasmic free calcium in retinal rod outer segment
Yau, K.-W., & Nakatani, K. (1985) · Nature · doi:10.1038/313579a0 · Cited by 379
Self-citationElectrogenic Na–Ca exchange in retinal rod outer segment
Yau, K.-W., & Nakatani, K. (1984) · Nature · doi:10.1038/311661a0 · Cited by 343
Self-citation
Metadata
- Authors
- Hodgkin, A. L., McNaughton, P. A., Nunn, B. J., & Yau, K. W.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1984-05
- Volume
- 350
- Issue
- 1
- Pages
- 649-680
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2082873326
- Cited by
- 108
- References
- 0
- FWCI
- 7.03
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of ions on retinal rods from Bufo marinus. https://app.cochat.ai/papers/10.1113/jphysiol.1984.sp015223
- The paper
- Hodgkin, A. L., McNaughton, P. A., Nunn, B. J., & Yau, K. W. (1984). Effect of ions on retinal rods from Bufo marinus. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1984.sp015223
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.