CoChat

Projection of pulmonary rapidly adapting receptors to the medulla of the cat: an antidromic mapping study.

Open access
Davies, R O, Kubin, L · 1986 · The Journal of Physiology
Cited by 81

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

The activity of pulmonary rapidly adapting receptor (r.a.r.) neurones was recorded extracellularly in the nodose ganglion of the decerebrate cat. The receptors were identified by their rapid adaptation to 'ramp and hold' hyperinflations of the lung. The antidromic mapping technique was used to determine the sites of projection and branching patterns within the nucleus of the tractus solitarius (n.t.s.) of eleven r.a.r.s. The medulla was explored with a stimulating electrode to activate the r.a.r.s. antidromically. In each penetration, depth‐threshold measurements were made for each antidromic response characterized by a distinct latency. Using the anatomical sites of the minimum threshold points, the locations of central branches of individual r.a.r.s. were determined. The main axons of all of them coursed within the tractus solitarius (t.s.) at levels from 2 mm rostral to 0.5 mm caudal to the obex. The axonal conduction velocities within the t.s. were 6.2‐9.7 m/s, where the peripheral conduction velocities were 11.2‐20.4 m/s (28 degrees C). Different latencies of response evoked in a single penetration were considered to indicate branching. The densest branching was found in the ipsilateral commissural subnucleus of the n.t.s. at levels 0.3‐1.3 mm caudal to the obex and, to a lesser degree, in the contralateral commissural subnucleus. All r.a.r.s. sent a few branches to the medial n.t.s. rostral to the obex. Four r.a.r.s. ramified in the ventrolateral n.t.s. where inspiratory cells are located. Depth‐threshold graphs were interpolated by best fitting parabolic equations: Ith = Ad2 + Bd + C; where Ith is the threshold current, d the corresponding depth of stimulation, and A, B and C are coefficients. Coefficient A is a measure of steepness of the parabola. The A coefficients were inversely related to the conduction velocity (v) of the stimulated branch. An analysis of the data from the present study (v = 5.0‐9.7 m/s) combined with data from the literature (v = 2.2‐85 m/s) led to a simple relationship between the A coefficient and the conduction velocity of the stimulated fibre: A = 6500/v, where A is expressed in microA/mm2 and v is expressed in m/s. Within the range 3‐35 m/s, the formula is useful in predicting the effective current spread when the conduction velocity is known, or to estimate the conduction velocity from the shape of a depth‐threshold curve. Two slowly adapting pulmonary stretch receptors (p.s.r.s) were studied.(ABSTRACT TRUNCATED AT 400 WORDS)

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1986.sp016035

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Davies, R. O., & Kubin, L.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1986-04
Volume
373
Issue
1
Pages
63-86
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2119055212
Cited by
81
References
1
FWCI
2.23
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.