The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Age and the transmittance of the human crystalline lens.
Open accessAbstract
1. Conflicting data both on the transmission of the human crystalline lens in the ultra‐violet part of the spectrum and on its variation with age necessitate a re‐examination of the subject. 2. Twenty‐four excised lenses in the age range of 0‐85 years were studied with a Perkin‐Elmer spectrophotometer between 327 and 700 nm. 3. Some lenses were homogenized and the homogenates were similarly examined. 4. A systematic increase in absorbance with age was observed both in the visible and the ultra‐violet parts of the spectrum. 5. An exponential function describes the data, facilitating comparison with, and prediction of, other values. 6. The absorbance of homogenized material was found to be predictable from that of intact lenses, and does not support the notion that mechanical trauma may account for high values in earlier studies.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Variation with Age of the Spectral Transmissivity of the Living Human Crystalline Lens
Said, F. S., & Weale, R. A. (1959) · Gerontology · doi:10.1159/000210900 · Cited by 335
Self-citationDevelopment of scotopic sensitivity and the absorption spectrum of the human ocular media
Werner, J. S. (1982) · Journal of the Optical Society of America · doi:10.1364/josa.72.000247 · Cited by 154
The yellow colour of the lens of man and other primates
Cooper, G. F., & Robson, J. G. (1969) · The Journal of Physiology · doi:10.1113/jphysiol.1969.sp008871 · Cited by 122
Zeimer, R. C., & Noth, J. (2009) · Ophthalmic Research · doi:10.1159/000265325 · Cited by 77
Biophysical aspects of corneal and lenticular transparency
Lerman, S. (1984) · Current Eye Research · doi:10.3109/02713688408997182 · Cited by 76
Human lenticular fluorescence and transmissivity, and their effects on vision
Weale, R. A. (1985) · Experimental Eye Research · doi:10.1016/s0014-4835(85)80004-x · Cited by 68
Self-citationULTRAVIOLET RADIATION IN THE AGING AND CATARACTOUS LENS: A Survey*
Lerman, S., & Borkman, R. F. (1978) · Acta Ophthalmologica · doi:10.1111/j.1755-3768.1978.tb00476.x · Cited by 58
Transparency and power of post-mortem human lenses: Variation with age and sex
Weale, R. A. (1983) · Experimental Eye Research · doi:10.1016/0014-4835(83)90110-0 · Cited by 28
Self-citationThe post-mortem preservation of the transmissivity of the human crystalline lens
Weale, R. A. (1985) · Experimental Eye Research · doi:10.1016/0014-4835(85)90037-5 · Cited by 12
Self-citation
Cited by
Bron, A. J., Vrensen, G. F. J. M., Koretz, J., Maraini, G., & Harding, J. J. (2000) · Ophthalmologica · doi:10.1159/000027475 · Cited by 280
Bernstein, P. S., Zhao, D.-Y., Wintch, S. W., Ermakov, I. V., McClane, R. W., & Gellermann, W. (2002) · Ophthalmology · doi:10.1016/s0161-6420(02)01173-9 · Cited by 254
Metadata
- Authors
- Weale, R. A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1988-01
- Volume
- 395
- Issue
- 1
- Pages
- 577-587
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2095563109
- Cited by
- 303
- References
- 9
- FWCI
- 2.41
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.