Estimating the timing of quantal releases during end‐plate currents at the frog neuromuscular junction.
Open accessThe DOI matches its Crossref record.
Abstract
1. Following motor nerve stimulation there is a period of greatly enhanced quantal release, called the early release period or ERP (Barrett & Stevens, 1972b). Until now, measurements of the probability of quantal releases at different points in the ERP have come from experiments in which quantal output was greatly reduced, so that the time of release of individual quanta could be detected or so that the latency to the release of the first quantum could be measured. 2. A method has been developed to estimate the timing of quantal release during the ERP that can be used at much higher levels of quantal output. The assumption is made that each quantal release generates an end‐plate current (EPC) that rises instantaneously and then decays exponentially. The peak amplitude of the quantal currents and the time constant for their decay are measured from miniature end‐plate currents (MEPCs). Then a number of EPCs are averaged, and the times of release of the individual quanta during the ERP estimated by a simple mathematical method for deconvolution derived by Cohen, Van der Kloot & Attwell (1981). 3. The deconvolution method was tested using data from preparations in high‐Mg2+ low‐Ca2+ solution. One test was to reconstitute the averaged EPCs from the estimated times of quantal release and the quantal currents, by using Fourier convolution. The reconstructions fit well to the originals. 4. Reconstructions were also made from averaged MEPCs which do not rise instantaneously and the estimated times of quantal release.(ABSTRACT TRUNCATED AT 250 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Intracellular calcium dependence of transmitter release rates at a fast central synapse
Schneggenburger, R., & Neher, E. (2000) · Nature · doi:10.1038/35022702 · Cited by 778
Hefft, S., & Jonas, P. (2005) · Nature Neuroscience · doi:10.1038/nn1542 · Cited by 583
Vesicular glutamate release from axons in white matter
Kukley, M., Capetillo-Zarate, E., & Dietrich, D. (2007) · Nature Neuroscience · doi:10.1038/nn1850 · Cited by 465
Multivesicular Release at Climbing Fiber-Purkinje Cell Synapses
Wadiche, J. I., & Jahr, C. E. (2001) · Neuron · doi:10.1016/s0896-6273(01)00488-3 · Cited by 372
Calmodulin Mediates Rapid Recruitment of Fast-Releasing Synaptic Vesicles at a Calyx-Type Synapse
Sakaba, T., & Neher, E. (2001) · Neuron · doi:10.1016/s0896-6273(01)00543-8 · Cited by 363
Metadata
- Authors
- Van der Kloot, W.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1988-08
- Volume
- 402
- Issue
- 1
- Pages
- 595-603
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2131844980
- Cited by
- 91
- References
- 0
- FWCI
- 0.52
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Estimating the timing of quantal releases during end‐plate currents at the frog neuromuscular junction. https://app.cochat.ai/papers/10.1113/jphysiol.1988.sp017224
- The paper
- Van der Kloot, W. (1988). Estimating the timing of quantal releases during end‐plate currents at the frog neuromuscular junction. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1988.sp017224
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.