Effects of peripheral and central chemoreflex activation on the isopnoeic rating of breathing in exercising humans.
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
1. Respiratory sensation during exercise is generally considered to be related to respiratory mechanical factors which may be manifest as an abnormal relationship between the force applied to the lungs and chest wall and the resulting motion (if any); that is, a ‘length‐tension’ inappropriateness (Campbell & Howell, 1963). This suggests that there should be a direct correlation between ventilation (VE) and the associated intensity of the perceived sensation, such that the sensation associated with a particular level of VE should remain essentially constant regardless of the source of respiratory stimulation. 2. In order to establish whether certain respiratory stimuli might be ‘dyspnoeagenic’ (i.e. capable of evoking an intensity of respiratory sensation out of proportion to their influence on VE), we investigated the influence of both peripheral chemoreflex activation (induced by isocapnic hypoxia) and central chemoreflex activation (induced by hypercapnic hyperoxia) on the intensity of respiratory sensation in seven healthy adults during moderate cycle ergometer exercise (i.e. below the lactate threshold, theta 1ac). 3. In each test, an ‘isopnoea’ was established for which a particular level of VE was sustained over a prolonged period (approximately 30 min) while the proportional contributions to the ventilatory drive from either exercise and the peripheral chemoreflex or from exercise and the central chemoreflex were slowly altered to new stable levels, without the subject's knowledge, VE, tidal volume, inspiratory and expiratory durations, mean inspiratory flow, and end‐tidal PCO2 and PO2 (PET,CO2, PET,O2) were monitored breath‐by‐breath. The intensity of respiratory sensation was rated with a visual analogue scale. 4. Isopnoeic ratings of respiratory sensation were systematically greater for peripheral chemoreflex activation by isocapnic hypoxia during exercise at 50% theta 1ac (for which the degree of peripheral chemoreflex activation, estimated by hyperoxic transition or ‘Dejours’ testing, averaged approximately 23% of the total VE), compared to 90% theta 1ac during isocapnic hyperoxia. Ratings during exercise at 50% theta 1ac for central chemoreflex activation by hypercapnic hyperoxia were not systematically different from 90% theta 1ac during isocapnic hyperoxia, however. 5. As VE was stable throughout each isopnoea and the MVV (maximum voluntary ventilation) was uninfluenced by the test condition, the dyspnoea index (VE x 100/MVV) was not affected. Breathing pattern was also unaffected. 6. We conclude that in normal subjects exercising moderately, activation of the peripheral chemoreceptors by isocapnic hypoxia evokes an intensity of respiratory sensation which is out of proportion to that evoked by an isopnoeic stimulation of the central chemoreceptors with hypercapnic hyperoxia at the same level of exercise.(ABSTRACT TRUNCATED AT 400 WORDS)
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Breathlessness during exercise with and without resistive loading
el-Manshawi, A., Killian, K. J., Summers, E., & Jones, N. L. (1986) · Journal of Applied Physiology · doi:10.1152/jappl.1986.61.3.896 · Cited by 211
Cited by
Dyspnea: Mechanisms, Assessment, and Management: A Consensus Statement
(1999) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/ajrccm.159.1.ats898 · Cited by 1,052
Dyspnea Mechanisms, Assessment and Management: A Consensus Statement
Editorial, A. (2005) · PULMONOLOGIYA · doi:10.18093/0869-0189-2005-0-2-9-36 · Cited by 808
Recommendations on the use of exercise testing in clinical practice
Palange, P., Ward, S. A., Carlsen, K.-H., Casaburi, R., Gallagher, C. G., Gosselink, R., O'Donnell, D. E., Puente-Maestu, L., Schols, A. M., Singh, S., et al. (2007) · European Respiratory Journal · doi:10.1183/09031936.00046906 · Cited by 718
Self-citationPathophysiology of Dyspnea in Chronic Obstructive Pulmonary Disease: A Roundtable
O'Donnell, D. E., Banzett, R. B., Carrieri-Kohlman, V., Casaburi, R., Davenport, P. W., Gandevia, S. C., Gelb, A. F., Mahler, D. A., & Webb, K. A. (2007) · Proceedings of the American Thoracic Society · doi:10.1513/pats.200611-159cc · Cited by 380
Somfay, A., Porszasz, J., Lee, S. M., & Casaburi, R. (2001) · European Respiratory Journal · doi:10.1183/09031936.01.00082201 · Cited by 339
Metadata
- Authors
- Ward, S. A., & Whipp, B. J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1989-04
- Volume
- 411
- Issue
- 1
- Pages
- 27-43
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2052964857
- Cited by
- 58
- References
- 1
- FWCI
- 1.19
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.