CoChat

Active ion transport pathways in the bovine retinal pigment epithelium.

Open access
Miller, S S, Edelman, J L · 1990 · The Journal of Physiology
Cited by 140

The DOI matches its Crossref record.

Abstract

1. Radioactive tracer flux measurements demonstrate that active ion transport across the isolated bovine retinal pigment epithelium (RPE)‐choroid preparation can be maintained for hours after the eye is enucleated and the tissue removed from the eye. 2. It has been shown that 86Rb tracer fluxes can be used to monitor potassium (K+) transport across bull‐frog RPE. In bovine RPE, net 86Rb (K+) absorption is zero. Apical barium (Ba2+) elevated active K+ absorption from zero to approximately 0.3 mu equiv cm‐2 h‐1. This Ba2(+)‐induced increase in active K+ absorption was inhibited either by ouabain or bumetanide in the apical bath. 3. In control Ringer solution, buffered with bicarbonate and CO2, the RPE‐choroid actively absorbs chloride (Cl‐) at a rate of approximately 0.5 mu equiv cm‐2 h‐1. In contrast, sodium (Na+) is secreted at a rate of approximately 0.5 mu equiv cm‐2 h‐1. Chloride absorption was inhibited by apical bumetanide, and Na+ secretion was inhibited by apical ouabain. These drugs were only effective when placed in the solution bathing the apical or retinal side of the tissue. 4. Net Cl‐ absorption requires an exit mechanism at the basolateral membrane. DIDS (4,4'‐diisothiocyanostilbene‐2,2'‐disulphonic acid) in the basal bath completely inhibited net Cl‐ absorption in bicarbonate‐free Ringer solution. 5. These experiments show that the chloride transport pathway contains at least two components: (1) a bumetanide‐sensitive uptake mechanism at the apical membrane; and (2) an efflux mechanism at the basolateral membrane that is blocked by DIDS. 6. Three apical membrane mechanisms were identified that could help modulate [K+]o in the subretinal or extracellular space that separates the distal retina and the RPE apical membrane. They are: (1) an ouabain‐sensitive Na(+)‐K+ pump; (2) a bumetanide‐sensitive mechanism, the putative Na(+)‐K(+)‐Cl‐ co‐transporter; (3) a barium‐sensitive K+ channel that recycles, to the apical bath, most or all of the potassium that is actively taken up by the Na(+)‐K+ pump and the co‐transporter. 7. These data suggest that light‐induced alterations in subretinal potassium that occur in vivo can activate the chloride transport pathway and help modulate RPE intracellular Cl‐ during transitions between the light and dark.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1990.sp018067

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 140

Metadata

Authors
Miller, S. S., & Edelman, J. L.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1990-05
Volume
424
Issue
1
Pages
283-300
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1984625729
Cited by
140
References
0
FWCI
2.03
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Active ion transport pathways in the bovine retinal pigment epithelium. https://app.cochat.ai/papers/10.1113/jphysiol.1990.sp018067
The paper
Miller, S. S., & Edelman, J. L. (1990). Active ion transport pathways in the bovine retinal pigment epithelium. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1990.sp018067

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.