The DOI matches its Crossref record.
Excitation by irritant chemical substances of sensory afferent units in the cat's cornea.
Open accessAbstract
1. Single‐unit electrical activity was recorded from thin myelinated sensory nerve fibres innervating the cornea of deeply anaesthetized cats. 2. Based on their responses to mechanical (calibrated von Frey hairs), chemical (10 mM‐acetic acid and/or 616 mM‐NaCl) and thermal (ice‐cold or heat up to 51 degrees C) stimuli, corneal A delta fibres were classified as polymodal nociceptors (63%), high‐threshold mechanoceptors (22%) and mechano‐heat nociceptors (15%). Thin myelinated fibres responding only to cold were found in the limbus of the eye. 3. Application of 10 mM‐acetic acid on the corneal surface for 30 s evoked in polymodal fibres a brisk discharge of impulses often followed by a low‐frequency impulse activity. NaCl (616 mM) produced a more gradual and sustained firing response. 4. The responses of polymodal fibres to acid were proportional to extracellular pH values (pH range: 4.5‐6.0). After sensitization to repeated heating, most mechano‐heat units developed a sensitivity to acidic stimulation. 5. Topical 0.33 mM‐capsaicin excited polymodal nociceptors of the cornea; 5 min after capsaicin about 15% of these fibres were inactivated to all subsequent stimuli. In the rest of the fibres, chemical and thermal sensitivity disappeared after 0.33‐3.3 mM‐capsaicin, but mechanosensitivity was preserved. 6. Corneal mechanoceptors and limbal cold receptors were not affected by capsaicin (up to 33 mM). 7. These experiments demonstrate that the cornea of the cat is innervated by polymodal as well as mechanoceptive A delta nociceptors. In polymodal nociceptive fibres, mechanical and chemical sensitivities appear to be subserved by separate transduction mechanisms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dua, H. S., Said, D. G., Messmer, E. M., Rolando, M., Benitez-del-Castillo, J. M., Hossain, P. N., Shortt, A. J., Geerling, G., Nubile, M., Figueiredo, F. C., et al. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2018.04.003 · Cited by 404
In Vivo Confocal Microscopy of Corneal Nerves in Health and Disease
Cruzat, A., Qazi, Y., & Hamrah, P. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2016.09.004 · Cited by 364
Protons: small stimulants of capsaicin-sensitive sensory nerves
Bevan, S., & Geppetti, P. (1994) · Trends in Neurosciences · doi:10.1016/0166-2236(94)90149-x · Cited by 298
Malick, A., Strassman, R. M., & Burstein, R. (2000) · Journal of Neurophysiology · doi:10.1152/jn.2000.84.4.2078 · Cited by 274
Chapter 8. Tissue acidosis in nociception and pain
Reeh, P. W., & Steen, K. H. (1996) · Progress in Brain Research · doi:10.1016/s0079-6123(08)61085-7 · Cited by 265
Metadata
- Authors
- Belmonte, C., Gallar, J., Pozo, M. A., & Rebollo, I.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1991-06
- Volume
- 437
- Issue
- 1
- Pages
- 709-725
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2103490623
- Cited by
- 247
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Excitation by irritant chemical substances of sensory afferent units in the cat's cornea. https://app.cochat.ai/papers/10.1113/jphysiol.1991.sp018621
- The paper
- Belmonte, C., Gallar, J., Pozo, M. A., & Rebollo, I. (1991). Excitation by irritant chemical substances of sensory afferent units in the cat's cornea. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1991.sp018621
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.