Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 299

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Organization of motor output in slow finger movements in man.

Open access
Vallbo, A B, Wessberg, J·1993·The Journal of Physiology

Abstract

1. Slow finger movements were analysed in normal human subjects with regard to kinematics and EMG activity of the long finger muscles. Surface EMG from the finger extensor and flexor muscles on the forearm was recorded along with angular position and angular velocity during voluntary ramp movements at single metacarpophalangeal joints. Angular acceleration was computed from the velocity record. 2. It was found that movements were not smooth but characterized by steps or discontinuities, often recurring at intervals of 100‐125 ms, yielding velocity and acceleration profiles dominated by 8‐10 Hz cycles. The discontinuities were manifest from the very first trial and thus not dependent on training. Their amplitude and amount varied between subjects but were relatively stable for the individual subject. 3. The 8‐10 Hz cycles were seen with voluntary ramp movements of widely varying velocities, higher velocities being associated with larger steps recurring with the same repetition rate as the small steps of slow voluntary ramps. Maximal step amplitude observed was more than one order of magnitude larger than physiological tremor. 4. The individual 8‐10 Hz cycle was asymmetrical in that decelerations usually reached higher peaks than the preceding acceleration, suggesting that the antagonist contributed with a braking action. Moreover, in very slow voluntary ramps, the movement cycles were often interspaced by periods of zero velocity, providing a highly non‐sinusoidal velocity profile. 5. The EMG of the agonist and the antagonist muscles was modulated in close relation to the accelerations and decelerations respectively of the individual movement cycle. These modulations were present in both extensor and flexor muscles, although they were more consistent and usually more prominent in the former. 6. The findings indicate that a feature of slow finger movements was an 8‐10 Hz periodic output to the muscular system, suggesting that slow finger movements are implemented by a series of biphasic force pulses, involving not only the shortening agonist muscle propelling the movement, but the antagonist muscle as well whose activity increased shortly after the agonist and contributed to a sharp deceleration of the individual step of movement. 7. It is proposed, as a hypothesis, that this biphasic motor output may reflect a similar organization of the descending motor command for slow finger movements. Hence, this command would include a series of biphasic pulses, concatenated at a rate of 8‐10 per second and a pulse‐height regulator capable of setting the size of the pulse and thus the overall speed of the movement.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1993.sp019837

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 299

Metadata

Authors
Vallbo, A. B., & Wessberg, J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1993-09
Volume
469
Issue
1
Pages
673-691
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2011305518
Cited by
299
References
1
FWCI
2.18
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Organization of motor output in slow finger movements in man. https://app.cochat.ai/papers/10.1113/jphysiol.1993.sp019837
The paper
Vallbo, A. B., & Wessberg, J. (1993). Organization of motor output in slow finger movements in man. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1993.sp019837

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.