Student or educator? Sign up with your school email and get 6 months of Pro free.
CoChat
Cited by 179

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

The effect of sleep on reflex genioglossus muscle activation by stimuli of negative airway pressure in humans.

Open access
Horner, R L, Innes, J A, Morrell, M J, Shea, S A, Guz, A · 1994 · The Journal of Physiology

Abstract

The present study was designed to determine the effect of sleep on reflex pharyngeal dilator muscle activation by stimuli of negative airway pressure in human subjects. Intra‐oral bipolar surface electrodes were used to record genioglossus electromyogram (EMG) responses to 500 ms duration pressure stimuli of 0 and ‐25 cmH2O applied, via a face‐mask, in four normal subjects. Stimuli were applied during early inspiration in wakefulness and in periods of non‐rapid‐eye‐movement (non‐REM) sleep, defined by electroencephalographic (EEG) criteria. The rectified and integrated EMG responses to repeated interventions were bin averaged for the 0 and ‐25 cmH2O stimuli applied in wakefulness and sleep. Response latency was defined as the time when the EMG activity significantly increased above prestimulus levels. Response magnitude was quantified as the in ratio of the EMG activity for an 80 ms post‐stimulus period to an 80 ms prestimulus period; data from after the subject's voluntary reaction time for tongue protrusion (range, 150‐230 ms) were not analysed. Application of the ‐25 cmH2O stimuli caused genioglossus muscle activation in wakefulness and sleep, but in all subjects response magnitude was reduced in sleep (mean decrease, 61%; range, 52‐82%; P = 0.011, Student's paired t test). In addition, response latency was increased in sleep in each subject (mean latency awake, 38 ms; range, 30‐50 ms; mean latency asleep, 75 ms; range, 40‐110 ms; P = 0.072, Student's paired t test). Application of the ‐25 cmH2O stimuli caused arousal from sleep on 90% occasions, but in all cases the reflex genioglossus muscle responses (maximum latency, 110 ms) always proceeded any sign of EEG arousal (mean time to arousal, 643 ms; range, 424‐760 ms). These results show that non‐REM sleep attenuates reflex genioglossus muscle activation by stimuli of negative airway pressure. Attenuation of this reflex by sleep may impair the ability of the upper airway to defend itself from suction collapse by negative pressures generated during inspiration; this may have implications for the pathogenesis of obstructive sleep apnoea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.1994.sp020118

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 179

Metadata

Authors
Horner, R. L., Innes, J. A., Morrell, M. J., Shea, S. A., & Guz, A.
Venue
The Journal of Physiology
Publisher
Wiley
Published
1994-04
Volume
476
Issue
1
Pages
141-151
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1508765586
Cited by
179
References
4
FWCI
1.28
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.