Correlation between electrical activity and the size of rabbit sino‐atrial node cells.
Open accessAbstract
1. Single cells were isolated from rabbit sino‐atrial (SA) node by enzymatic dissociation. Spontaneous action potentials and membrane currents were recorded using the whole‐cell patch clamp technique to study the relationship between electrical activity and the size of the cells. 2. The size of SA node cells was estimated by measuring the cell capacitance. The cell capacitance of SA node cells ranged from 21.8 to 61.5 pF with a mean +/‐ S.E.M. of 38.2 +/‐ 1.3 pF (n = 61). 3. The action potential amplitude, maximum diastolic potential, take‐off potential and action potential upstroke velocity were greater in larger cells. The rate of diastolic depolarization was greater and the intrinsic spontaneous activity was faster in larger cells. 4. The density of hyperpolarization‐activated current (i(f)) was greater in larger cells, whereas the density of L‐type calcium current was not correlated with the size of SA node cells. 5. TTX‐sensitive sodium current (iNa) was absent in small cells with a capacitance of less than approximately 25 pF, and the density of iNa was greater in larger cells. 6. The greater density of iNa in larger cells may explain the higher upstroke velocity of the action potential in large cells, and the greater density of i(f) and iNa could be responsible for the faster intrinsic spontaneous activity of large cells. These results suggest that the SA node consists of electrophysiologically heterogeneous pacemaker cells with different electrical membrane properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The sinoatrial node, a heterogeneous pacemaker structure
Boyett, M. (2000) · Cardiovascular Research · doi:10.1016/s0008-6363(00)00135-8 · Cited by 698
Self-citationGenesis and Regulation of the Heart Automaticity
Mangoni, M. E., & Nargeot, J. (2008) · Physiological Reviews · doi:10.1152/physrev.00018.2007 · Cited by 600
New Insights Into Pacemaker Activity: Promoting Understanding of Sick Sinus Syndrome
Dobrzynski, H., Boyett, M. R., & Anderson, R. H. (2007) · Circulation · doi:10.1161/circulationaha.106.616011 · Cited by 429
Self-citationDirect conversion of quiescent cardiomyocytes to pacemaker cells by expression of Tbx18
Kapoor, N., Liang, W., Marbán, E., & Cho, H. C. (2013) · Nature Biotechnology · doi:10.1038/nbt.2465 · Cited by 321
What keeps us ticking: a funny current, a calcium clock, or both?
Lakatta, E. G., & DiFrancesco, D. (2009) · Journal of Molecular and Cellular Cardiology · doi:10.1016/j.yjmcc.2009.03.022 · Cited by 291
Metadata
- Authors
- Honjo, H., Boyett, M. R., Kodama, I., & Toyama, J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 1996-11
- Volume
- 496
- Issue
- 3
- Pages
- 795-808
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W433083804
- Cited by
- 163
- References
- 0
- FWCI
- 2.60
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Correlation between electrical activity and the size of rabbit sino‐atrial node cells. https://app.cochat.ai/papers/10.1113/jphysiol.1996.sp021728
- The paper
- Honjo, H., Boyett, M. R., Kodama, I., & Toyama, J. (1996). Correlation between electrical activity and the size of rabbit sino‐atrial node cells. The Journal of Physiology. https://doi.org/10.1113/jphysiol.1996.sp021728
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.