The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the Mouse
Open accessAbstract
The most sensitive response in the dark‐adapted electroretinogram (ERG), the scotopic threshold response (STR) which originates from the proximal retina, has been identified in several mammals including humans, but previously not in the mouse. The current study established the presence and assessed the nature of the mouse STR. ERGs were recorded from adult wild‐type C57/BL6 mice anaesthetized with ketamine (70 mg kg−1) and xylazine (7 mg kg−1). Recordings were between DTL fibres placed under contact lenses on the two eyes. Monocular test stimuli were brief flashes (λ max 462 nm; ‐6.1 to +1.8 log scotopic Troland seconds(sc td s)) under fully dark‐adapted conditions and in the presence of steady adapting backgrounds (‐3.2 to ‐1.7 log sc td). For the weakest test stimuli, ERGs consisted of a slow negative potential maximal ≈200 ms after the flash, with a small positive potential preceding it. The negative wave resembled the STR of other species. As intensity was increased, the negative potential saturated but the positive potential (maximal ≈110 ms) continued to grow as the b‐wave. For stimuli that saturated the b‐wave, the a‐wave emerged. For stimulus strengths up to those at which the a‐wave emerged, ERG amplitudes measured at fixed times after the flash (110 and 200 ms) were fitted with a model assuming an initially linear rise of response amplitude with intensity, followed by saturation of five components of declining sensitivity: a negative STR (nSTR), a positive STR (pSTR), a positive scotopic response (pSR), PII (the bipolar cell component) and PIII (the photoreceptor component). The nSTR and pSTR were approximately 3 times more sensitive than the pSR, which was approximately 7 times more sensitive than PII. The sensitive positive components dominated the b‐wave up to > 5 % of its saturated amplitude. Pharmacological agents that suppress proximal retinal activity (e.g. GABA) minimized the pSTR, nSTR and pSR, essentially isolating PII which rose linearly with intensity before showing hyperbolic saturation. The nSTR, pSTR and pSR were desensitized by weaker backgrounds than those desensitizing PII. In conclusion, ERG components of proximal retinal origin that are more sensitive to test flashes and adapting backgrounds than PII provide the ‘threshold’ negative and positive (b‐wave) responses of the mouse dark‐adapted ERG. These results support the use of the mouse ERG in studies of proximal retinal function.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
B-wave of the electroretinogram. A reflection of ON bipolar cell activity
Stockton, R. A., & Slaughter, M. M. (1989) · The Journal of general physiology · doi:10.1085/jgp.93.1.101 · Cited by 446
Pugh, E. N., Falsini, B., & Lyubarsky, A. L. (1998) · Photostasis and Related Phenomena · doi:10.1007/978-1-4899-1549-8_7 · Cited by 117
Cited by
Gargini, C., Terzibasi, E., Mazzoni, F., & Strettoi, E. (2007) · Journal of Comparative Neurology · doi:10.1002/cne.21144 · Cited by 493
Electroretinography in glaucoma diagnosis
Wilsey, L. J., & Fortune, B. (2016) · Current Opinion in Ophthalmology · doi:10.1097/icu.0000000000000241 · Cited by 113
Lotfi, P., Tse, D. Y., Di Ronza, A., Seymour, M. L., Martano, G., Cooper, J. D., Pereira, F. A., Passafaro, M., Wu, S. M., & Sardiello, M. (2018) · Autophagy · doi:10.1080/15548627.2018.1474313 · Cited by 106
ERG changes in albino and pigmented mice after optic nerve transection
Alarcón-Martínez, L., Avilés-Trigueros, M., Galindo-Romero, C., Valiente-Soriano, J., Agudo-Barriuso, M., Villa, P. D. L., Villegas-Pérez, M. P., & Vidal-Sanz, M. (2010) · Vision Research · doi:10.1016/j.visres.2010.08.014 · Cited by 61
Loss of Circadian Photoentrainment and Abnormal Retinal Electrophysiology in Math5 Mutant Mice
Brzezinski, J. A., Brown, N. L., Tanikawa, A., Bush, R. A., Sieving, P. A., Vitaterna, M. H., Takahashi, J. S., & Glaser, T. (2005) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.04-1123 · Cited by 60
Metadata
- Authors
- Saszik, S. M., Robson, J. G., & Frishman, L. J.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2002-09
- Volume
- 543
- Issue
- 3
- Pages
- 899-916
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1981121080
- Cited by
- 295
- References
- 2
- FWCI
- 3.13
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the Mouse. https://app.cochat.ai/papers/10.1113/jphysiol.2002.019703
- The paper
- Saszik, S. M., Robson, J. G., & Frishman, L. J. (2002). The Scotopic Threshold Response of the Dark‐Adapted Electroretinogram of the Mouse. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2002.019703
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.