CoChat

ATP and heat production in human skeletal muscle during dynamic exercise: higher efficiency of anaerobic than aerobic ATP resynthesis

Open access
Krustrup, Peter, Ferguson, Richard A., Kjær, Michael, Bangsbo, Jens · 2003 · The Journal of Physiology
Cited by 129

The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.

Abstract

The aim of the present study was to simultaneously examine skeletal muscle heat production and ATP turnover in humans during dynamic exercise with marked differences in aerobic metabolism. This was done to test the hypothesis that efficiency is higher in anaerobic than aerobic ATP resynthesis. Six healthy male subjects performed 90 s of low intensity knee‐extensor exercise with (OCC) and without thigh occlusion (CON‐LI) as well as 90 s of high intensity exercise (CON‐HI) that continued from the CON‐LI bout. Muscle heat production was determined by continuous measurements of muscle heat accumulation and heat release to the blood. Muscle ATP production was quantified by repeated measurements of thigh oxygen uptake as well as blood and muscle metabolite changes. All temperatures of the thigh were equalized to ≈37 °C prior to exercise by a water‐perfused heating cuff. Oxygen uptake accounted for 80 ± 2 and 59 ± 4 %, respectively, of the total ATP resynthesis in CON‐LI and CON‐HI, whereas it was negligible in OCC. The rise in muscle temperature was lower (P < 0.05) in OCC than CON‐LI (0.32 ± 0.04 vs. 0.37 ± 0.03 °C). The mean rate of heat production was also lower (P < 0.05) in OCC than CON‐LI (36 ± 4 vs. 57 ± 4 J s−1). Mechanical efficiency was 52 ± 4 % after 15 s of OCC and remained constant, whereas it decreased (P < 0.05) from 56 ± 5 to 32 ± 3 % during CON‐LI. During CON‐HI, mechanical efficiency transiently increased (P < 0.05) to 47 ± 4 %, after which it decreased (P < 0.05) to 36 ± 3 % at the end of CON‐HI. Assuming a fully coupled mitochondrial respiration, the ATP turnover per unit of work was calculated to be unaltered during OCC (≈20 mmol ATP kJ−1), whereas it increased (P < 0.05) from 21 ± 4 to 29 ± 3 mmol ATP kJ−1 during CON‐LI and further (P < 0.05) to 37 ± 3 mmol ATP kJ−1 during CON‐HI. The present data confirm the hypothesis that heat loss is lower in anaerobic ATP resynthesis than in oxidative phosphorylation and can in part explain the finding that efficiency declines markedly during dynamic exercise. In addition, the rate of ATP turnover apparently increases during constant load low intensity exercise. Alternatively, mitochondrial efficiency is lowered as exercise progresses, since ATP turnover was unaltered during the ischaemic exercise bout.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2002.035089

Cites

5 of 5 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 5 references

Cited by

See all 129

Metadata

Authors
Krustrup, P., Ferguson, R. A., Kjær, M., & Bangsbo, J.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2003-05
Volume
549
Issue
1
Pages
255-269
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2162451109
Cited by
129
References
5
FWCI
15.35
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: ATP and heat production in human skeletal muscle during dynamic exercise: higher efficiency of anaerobic than aerobic ATP resynthesis. https://app.cochat.ai/papers/10.1113/jphysiol.2002.035089
The paper
Krustrup, P., Ferguson, R. A., Kjær, M., & Bangsbo, J. (2003). ATP and heat production in human skeletal muscle during dynamic exercise: higher efficiency of anaerobic than aerobic ATP resynthesis. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2002.035089

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.