The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Regulation of tissue oxygen levels in the mammalian lens
Abstract
Opacification of the lens nucleus is a major cause of blindness and is thought to result from oxidation of key cellular components. Thus, long‐term preservation of lens clarity may depend on the maintenance of hypoxia in the lens nucleus. We mapped the distribution of dissolved oxygen within isolated bovine lenses and also measured the rate of oxygen consumption (Q̇O2) by lenses, or parts thereof. To assess the contribution of mitochondrial metabolism to the lens oxygen budget, we tested the effect of mitochondrial inhibitors on Q̇O2 and partial pressure of oxygen (PO2). The distribution of mitochondria was mapped in living lenses by 2‐photon microscopy. We found that a steep gradient of PO2 was maintained within the tissue, leading to PO2 < 2 mmHg in the core. Mitochondrial respiration accounted for approximately 90% of the oxygen consumed by the lens; however, PO2 gradients extended beyond the boundaries of the mitochondria‐containing cell layer, indicating the presence of non‐mitochondrial oxygen consumers. Time constants for oxygen consumption in various regions of the lens and an effective oxygen diffusion coefficient were calculated from a diffusion–consumption model. Typical values were 3 × 10−5 cm 2 s−1 for the effective diffusion coefficient and a 5 min time constant for oxygen consumption. Surprisingly, the calculated time constants did not differ between differentiating fibres (DF) that contained mitochondria and mature fibres (MF) that did not. Based on these parameters, DF cells were responsible for approximately 88% of lens oxygen consumption. A modest reduction in tissue temperature resulted in a marked decrease in Q̇O2 and the subsequent flooding of the lens core with oxygen. This phenomenon may be of clinical relevance because cold, oxygen‐rich solutions are often infused into the eye during intraocular surgery. Such procedures are associated with a strikingly high incidence of postsurgical nuclear cataract.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Syncope, cerebral perfusion, and oxygenation
Van Lieshout, J. J., Wieling, W., Karemaker, J. M., & Secher, N. H. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00260.2002 · Cited by 365
Interactions between bioenergetics and mitochondrial biogenesis
Leary, S. C., Battersby, B. J., Hansford, R. G., & Moyes, C. D. (1998) · Biochimica et Biophysica Acta (BBA) - Bioenergetics · doi:10.1016/s0005-2728(98)00105-4 · Cited by 118
Cited by
Age-related nuclear cataract—oxidation is the key
Truscott, R. J. W. (2005) · Experimental Eye Research · doi:10.1016/j.exer.2004.12.007 · Cited by 857
Self-citationVinson, J. A. (2006) · Pathophysiology · doi:10.1016/j.pathophys.2006.05.006 · Cited by 288
Dimerization and oxidation of tryptophan in UV-A photolysis sensitized by kynurenic acid
Sormacheva, E. D., Sherin, P. S., & Tsentalovich, Y. P. (2017) · Free Radical Biology and Medicine · doi:10.1016/j.freeradbiomed.2017.10.007 · Cited by 37
Comprehensive Nanorobotic Control of Human Morbidity and Aging
Freitas, R. A. (2010) · The Future of Aging · doi:10.1007/978-90-481-3999-6_23 · Cited by 16
Metadata
- Authors
- McNulty, R., Wang, H., Mathias, R. T., Ortwerth, B. J., Truscott, R. J. W., & Bassnett, S.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2004-09
- Volume
- 559
- Issue
- 3
- Pages
- 883-898
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W2156417130
- Cited by
- 181
- References
- 2
- FWCI
- 3.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.