Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 222

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

The ventilatory responsiveness to CO2 below eupnoea as a determinant of ventilatory stability in sleep

Dempsey, Jerome A., Smith, Curtis A., Przybylowski, Tadeuez, Chenuel, Bruno, Xie, Ailiang, Nakayama, Hideaki, Skatrud, James B.·2004·The Journal of Physiology

Abstract

Sleep unmasks a highly sensitive hypocapnia‐induced apnoeic threshold, whereby apnoea is initiated by small transient reductions in arterial CO 2 pressure (PaCO2) below eupnoea and respiratory rhythm is not restored until PaCO2 has risen significantly above eupnoeic levels. We propose that the ‘CO 2 reserve’ (i.e. the difference in PaCO2 between eupnoea and the apnoeic threshold (AT)), when combined with ‘plant gain’ (or the ventilatory increase required for a given reduction in PaCO2) and ‘controller gain’ (ventilatory responsiveness to CO 2 above eupnoea) are the key determinants of breathing instability in sleep. The CO 2 reserve varies inversely with both plant gain and the slope of the ventilatory response to reduced CO 2 below eupnoea; it is highly labile in non‐random eye movement (NREM) sleep. With many types of increases or decreases in background ventilatory drive and PaCO2, the slope of the ventilatory response to reduced PaCO2 below eupnoea remains unchanged from control. Thus, the CO 2 reserve varies inversely with plant gain, i.e. it is widened with hyperventilation and narrowed with hypoventilation, regardless of the stimulus and whether it acts primarily at the peripheral or central chemoreceptors. However, there are notable exceptions, such as hypoxia, heart failure, or increased pulmonary vascular pressures, which all increase the slope of the CO 2 response below eupnoea and narrow the CO 2 reserve despite an accompanying hyperventilation and reduced plant gain. Finally, we review growing evidence that chemoreceptor‐induced instability in respiratory motor output during sleep contributes significantly to the major clinical problem of cyclical obstructive sleep apnoea.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2004.072371

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

Metadata

Authors
Dempsey, J. A., Smith, C. A., Przybylowski, T., Chenuel, B., Xie, A., Nakayama, H., & Skatrud, J. B.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2004-10
Volume
560
Issue
1
Pages
1-11
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1559698714
Cited by
222
References
1
FWCI
3.38
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.