Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 366

The DOI matches its Crossref record; 31 of the 31 references it cites were found in a registry or an index.

Heterozygous HIF‐1α deficiency impairs carotid body‐mediated systemic responses and reactive oxygen species generation in mice exposed to intermittent hypoxia

Open access
Peng, Ying‐Jie, Yuan, Guoxiang, Ramakrishnan, Deviprasadh, Sharma, Suresh D., Bosch‐Marce, Marta, Kumar, Ganesh K., Semenza, Gregg L., Prabhakar, Nanduri R.·2006·The Journal of Physiology

Abstract

Chronic intermittent hypoxia (CIH) occurs in patients with sleep apnoea and has adverse effects on multiple physiological functions. Previous studies have shown that reflexes arising from carotid bodies mediate CIH‐evoked cardio‐respiratory responses, and reactive oxygen species (ROS) play important roles in eliciting systemic responses to CIH. Very little is known about the molecular mechanisms underlying CIH. The transcriptional activator hypoxia‐inducible factor‐1 (HIF‐1) mediates a broad range of cellular and systemic responses to hypoxia, and HIF‐1 is activated in cell cultures exposed to IH. In the present study we examined whether CIH activates HIF‐1 and if so whether it contributes to cardio‐respiratory responses and ROS generation in mice. Experiments were performed on male littermate wild‐type (WT) and heterozygous (HET) mice partially deficient in HIF‐1α, the O 2 regulated subunit of the HIF‐1 complex. Both groups of mice were exposed to either 10 days of CIH (15 s of hypoxia followed by 5 min of normoxia, 9 episodes h−1, 8 h day−1) or to 10 days of 21% O 2 (controls). Carotid body response to hypoxia was augmented, and acute intermittent hypoxia (AIH) induced sensory long‐term facilitation (sLTF) of the chemoreceptor activity in CIH‐exposed WT mice. In striking contrast, hypoxic sensory response was unaffected and AIH was ineffective in eliciting sLTF in CIH‐exposed HET mice. Analysis of cardio‐respiratory responses in CIH‐exposed WT mice revealed augmented hypoxic ventilatory response, LTF of breathing, elevated blood pressures and increased plasma noradrenaline. In striking contrast these responses were either absent or attenuated in HET mice exposed to CIH. In CIH‐exposed WT mice, ROS were elevated and this response was absent in HET mice. Manganese (III) tetrakis(1‐methyl‐4‐pyridyl) porphyrin pentachloride, a potent scavenger of superoxide, not only prevented CIH‐induced increases in ROS but also CIH‐evoked HIF‐1α up‐regulation in WT mice. These results indicate that: (a) HIF‐1 activation is critical for eliciting CIH‐induced carotid body‐mediated cardio‐respiratory responses; (b) CIH increases ROS; and (c) the effects of CIH involve complex positive interactions between HIF‐1 and ROS.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2006.114033

Cites

31 of 31 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 31 references

Cited by

See all 366

Metadata

Authors
Peng, Y., Yuan, G., Ramakrishnan, D., Sharma, S. D., Bosch‐Marce, M., Kumar, G. K., Semenza, G. L., & Prabhakar, N. R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2006-11-24
Volume
577
Issue
2
Pages
705-716
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W2153376781
Cited by
366
References
31
FWCI
9.31
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Heterozygous HIF‐1α deficiency impairs carotid body‐mediated systemic responses and reactive oxygen species generation in mice exposed to intermittent hypoxia. https://app.cochat.ai/papers/10.1113/jphysiol.2006.114033
The paper
Peng, Y., Yuan, G., Ramakrishnan, D., Sharma, S. D., Bosch‐Marce, M., Kumar, G. K., Semenza, G. L., & Prabhakar, N. R. (2006). Heterozygous HIF‐1α deficiency impairs carotid body‐mediated systemic responses and reactive oxygen species generation in mice exposed to intermittent hypoxia. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2006.114033

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.