The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Prospective targeting and control of end‐tidal CO2 and O2 concentrations
Open accessAbstract
Current methods of forcing end‐tidal PCO2 (PETCO2) and PO2 (PETO2) rely on breath‐by‐breath adjustment of inspired gas concentrations using feedback loop algorithms. Such servo‐control mechanisms are complex because they have to anticipate and compensate for the respiratory response to a given inspiratory gas concentration on a breath‐by‐breath basis. In this paper, we introduce a low gas flow method to prospectively target and control PETCO2 and PETO2 independent of each other and of minute ventilation in spontaneously breathing humans. We used the method to change PETCO2 from control (40 mmHg for PETCO2 and 100 mmHg for PETO2) to two target PETCO2 values (45 and 50 mmHg) at iso‐oxia (100 mmHg), PETO2 to two target values (200 and 300 mmHg) at normocapnia (40 mmHg), and PETCO2 with PETO2 simultaneously to the same targets (45 with 200 mmHg and 50 with 300 mmHg). After each targeted value, PETCO2 and PETO2 were returned to control values. Each state was maintained for 30 s. The average difference between target and measured values for PETCO2 was ± 1 mmHg, and for PETO2 was ± 4 mmHg. PETCO2 varied by ± 1 mmHg and PETO2 by ± 5.6 mmHg (s.d.) over the 30 s stages. This degree of control was obtained despite considerable variability in minute ventilation between subjects (± 7.6 l min−1). We conclude that targeted end‐tidal gas concentrations can be attained in spontaneously breathing subjects using this prospective, feed‐forward, low gas flow system.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Respiratory physiology: The essentials
(1975) · British Journal of Diseases of the Chest · doi:10.1016/0007-0971(75)90100-x · Cited by 1,120
Hypoxic ventilatory drive in normal man
Weil, J. V., Byrne-Quinn, E., Sodal, I. E., Friesen, W. O., Underhill, B., Filley, G. F., & Grover, R. F. (1970) · Journal of Clinical Investigation · doi:10.1172/jci106322 · Cited by 436
Respiratory Physiology—the essentials
Nunn, J. F. (1975) · British Journal of Anaesthesia · doi:10.1093/bja/47.1.88-b · Cited by 259
Floyd, T. F., Clark, J. M., Gelfand, R., Detre, J. A., Ratcliffe, S., Guvakov, D., Lambertsen, C. J., & Eckenhoff, R. G. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00303.2003 · Cited by 258
Dynamics of the cerebral blood flow response to step changes in end-tidal PCO2 and PO2 in humans
Poulin, M. J., Liang, P. J., & Robbins, P. A. (1996) · Journal of Applied Physiology · doi:10.1152/jappl.1996.81.3.1084 · Cited by 257
ARCON: a novel biology-based approach in radiotherapy
Kaanders, J. H., Bussink, J., & van der Kogel, A. J. (2002) · The Lancet Oncology · doi:10.1016/s1470-2045(02)00929-4 · Cited by 256
Carbon dioxide and the critically ill—too little of a good thing?
Laffey, J. G., & Kavanagh, B. P. (1999) · The Lancet · doi:10.1016/s0140-6736(99)02388-0 · Cited by 240
The Lung. Clinical Physiology and Pulmonary Function Tests.
(1963) · Annals of Internal Medicine · doi:10.7326/0003-4819-58-3-557_2 · Cited by 239
Ide, K., Eliasziw, M., & Poulin, M. J. (2003) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01186.2002 · Cited by 225
Cerebrovascular Response to Carbon Dioxide in Patients with Congestive Heart Failure
Xie, A., Skatrud, J. B., Khayat, R., Dempsey, J. A., Morgan, B., & Russell, D. (2005) · American Journal of Respiratory and Critical Care Medicine · doi:10.1164/rccm.200406-807oc · Cited by 177
Cited by
Resting-state fMRI confounds and cleanup
Murphy, K., Birn, R. M., & Bandettini, P. A. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.04.001 · Cited by 666
Regional brain blood flow in man during acute changes in arterial blood gases
Willie, C. K., Macleod, D. B., Shaw, A. D., Smith, K. J., Tzeng, Y. C., Eves, N. D., Ikeda, K., Graham, J., Lewis, N. C., Day, T. A., et al. (2012) · The Journal of Physiology · doi:10.1113/jphysiol.2012.228551 · Cited by 483
The Ventilatory Response to Hypoxia in Mammals: Mechanisms, Measurement, and Analysis
Teppema, L. J., & Dahan, A. (2010) · Physiological Reviews · doi:10.1152/physrev.00012.2009 · Cited by 381
Measuring cerebrovascular reactivity: what stimulus to use?
Fierstra, J., Sobczyk, O., Battisti‐Charbonney, A., Mandell, D. M., Poublanc, J., Crawley, A. P., Mikulis, D. J., Duffin, J., & Fisher, J. A. (2013) · The Journal of Physiology · doi:10.1113/jphysiol.2013.259150 · Cited by 318
Self-citationSelective reduction of blood flow to white matter during hypercapnia corresponds with leukoaraiosis
Mandell, D. M., Han, J. S., Poublanc, J., Crawley, A. P., Kassner, A., Fisher, J. A., & Mikulis, D. J. (2008) · Stroke · doi:10.1161/strokeaha.107.501692 · Cited by 114
Self-citation
Metadata
- Authors
- Slessarev, M., Han, J., Mardimae, A., Prisman, E., Preiss, D., Volgyesi, G., Ansel, C., Duffin, J., & Fisher, J. A.
- Venue
- The Journal of Physiology
- Publisher
- Wiley
- Published
- 2007-06-06
- Volume
- 581
- Issue
- 3
- Pages
- 1207-1219
- ISSN
- 0022-3751 (ISSN-L)
- 1469-7793
- OpenAlex
- W1642429626
- Cited by
- 304
- References
- 20
- FWCI
- 8.33
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Prospective targeting and control of end‐tidal CO2 and O2 concentrations. https://app.cochat.ai/papers/10.1113/jphysiol.2007.129395
- The paper
- Slessarev, M., Han, J., Mardimae, A., Prisman, E., Preiss, D., Volgyesi, G., Ansel, C., Duffin, J., & Fisher, J. A. (2007). Prospective targeting and control of end‐tidal CO2 and O2 concentrations. The Journal of Physiology. https://doi.org/10.1113/jphysiol.2007.129395
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.