Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 167

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Human lymphatic pumping measured in healthy and lymphoedematous arms by lymphatic congestion lymphoscintigraphy

Open access
Modi, S., Stanton, A. W. B., Svensson, W. E., Peters, A. M., Mortimer, P. S., Levick, J. R.·2007·The Journal of Physiology

Abstract

Axillary surgery for breast cancer partially obstructs lymph outflow from the arm, chronically raising the lymphatic smooth muscle afterload. This may lead to pump failure, as in hypertensive cardiac failure, and could explain features of breast cancer treatment‐related lymphoedema (BCRL) such as its delayed onset. A new method was developed to measure human lymphatic contractility non‐invasively and test the hypothesis of contractile impairment. 99m Tc‐human IgG (Tc‐HIG), injected into the hand dermis, drained into the arm lymphatic system which was imaged using a gamma‐camera. Lymph transit time from hand to axilla, ttransit, was 9.6 ± 7.2 min (mean ±s.d.) (velocity 8.9 cm min−1) in seven normal subjects. To assess lymphatic contractility, a sphygmomanometer cuff around the upper arm was inflated to 60 mmHg (Pcuff) before 99m Tc‐HIG injection and maintained for >> ttransit. When Pcuff exceeded the maximum pressure generated by the lymphatic pump (Ppump), radiolabelled lymph was held up at the distal cuff border. Pcuff was then lowered in 10 mmHg steps until 99m Tc‐HIG began to flow under the cuff to the axilla, indicating Ppump≥Pcuff. In 16 normal subjects Ppump was 39 ± 14 mmHg. Ppump was 38% lower in 16 women with BCRL, namely 24 ± 19 mmHg (P= 0.014, Student's unpaired t test), and correlated negatively with the degree of swelling (12–56%). Blood radiolabel accumulation proved an unreliable measure of lymphatic pump function. Lymphatic congestion lymphoscintigraphy thus provided a quantitative measure of human lymphatic contractility without surgical cut‐down, and the results supported the hypothesis of lymphatic pump failure in BCRL.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1113/jphysiol.2007.130401

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 167

Metadata

Authors
Modi, S., Stanton, A. W. B., Svensson, W. E., Peters, A. M., Mortimer, P. S., & Levick, J. R.
Venue
The Journal of Physiology
Publisher
Wiley
Published
2007-08
Volume
583
Issue
1
Pages
271-285
ISSN
  • 0022-3751 (ISSN-L)
  • 1469-7793
OpenAlex
W1939019704
Cited by
167
References
1
FWCI
4.68
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.