CoChat

Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects

The DOI matches its Crossref record; the references it cites are not checked yet.

Abstract

In 12-lead electrocardiography (ECG), detection of myocardial ischemia is based on ST-segment changes in exercise testing. Magnetocardiography (MCG) is a complementary method to the ECG for a noninvasive study of the electric activity of the heart. In the MCG, ST-segment changes due to stress have also been found in healthy subjects. To further study the normal response to exercise, we performed MCG mappings in 12 healthy volunteers during supine bicycle ergometry. We also recorded body surface potential mapping (BSPM) with 123 channels using the same protocol. In this paper we compare, for the first time, multichannel MCG recorded in bicycle exercise testing with BSPM over the whole thorax in middle-aged healthy subjects. We quantified changes induced by the exercise in the MCG and BSPM with parameters based on signal amplitude, and correlation between signal distributions at rest and after exercise. At the ST-segment and T-wave apex, the exercise induced a magnetic field component outward the precordium and the minimum value of the MCG signal over the mapped area was found to be amplified. The response to exercise was smaller in the BSPM than in the MCG. A negative component in the MCG signal at the repolarization period of the cardiac cycle should be considered as a normal response to exercise. Therefore, maximum ST-segment depression over the mapped area in the MCG may not be an eligible parameter when evaluating the presence of ischemia.

Overview

Integrity signals

Registry

Crossref · 10.1114/1.1376388

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

The citation lists are queued

They are fetched later and appear here then.

References 21 · Cited by 42

Metadata

Authors
Takala, P., Hänninen, H., Montonen, J., Mäkijärvi, M., Nenonen, J., Oikarinen, L., Simelius, K., Toivonen, L., & Katila, T.
Affiliations
Helsinki University Hospital (FI)
Venue
Annals of Biomedical Engineering
Published
2001-06
Volume
29
Issue
6
Pages
501-509
ISSN
0090-6964 (ISSN-L)
OpenAlex
W1983621063
Cited by
42
References
21
Citations by year
2026: 2 · 2025: 1 · 2024: 4 · 2023: 3 · 2022: 3 · 2019: 1 · 2017: 2 · 2015: 1 · 2014: 2
FWCI
2.68
Type
journal article
Language
en
Open access
closed
Locations
  • Annals of Biomedical Engineering (publishedVersion)
  • PubMed (publishedVersion)
Funders
Jenny ja Antti Wihurin Rahasto
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Cardiac Imaging and Diagnostics
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
Keywords
magnetocardiography, body surface potential mapping, exercise testing, ST-segment changes, myocardial ischemia, T wave, cycle ergometry, cardiac repolarization, healthy volunteers, cardiac magnetic field
MeSH terms
Biomedical Engineering, Electrocardiography, Exercise Test, Female, Humans, Magnetics, Male, Middle Aged, Signal Processing, Computer-Assisted, Myocardial Ischemia, Body Surface Potential Mapping

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects. https://app.cochat.ai/papers/10.1114/1.1376388
The paper
Takala, P., Hänninen, H., Montonen, J., Mäkijärvi, M., Nenonen, J., Oikarinen, L., Simelius, K., Toivonen, L., & Katila, T. (2001). Magnetocardiographic and Electrocardiographic Exercise Mapping in Healthy Subjects. Annals of Biomedical Engineering. https://doi.org/10.1114/1.1376388

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.