The DOI matches its Crossref record.
The Role of Flow-Independent Viscoelasticity in the Biphasic Tensile and Compressive Responses of Articular Cartilage
Abstract
A long-standing challenge in the biomechanics of connective tissues (e.g., articular cartilage, ligament, tendon) has been the reported disparities between their tensile and compressive properties. In general, the intrinsic tensile properties of the solid matrices of these tissues are dictated by the collagen content and microstructural architecture, and the intrinsic compressive properties are dictated by their proteoglycan content and molecular organization as well as water content. These distinct materials give rise to a pronounced and experimentally well-documented nonlinear tension–compression stress–strain responses, as well as biphasic or intrinsic extracellular matrix viscoelastic responses. While many constitutive models of articular cartilage have captured one or more of these experimental responses, no single constitutive law has successfully described the uniaxial tensile and compressive responses of cartilage within the same framework. The objective of this study was to combine two previously proposed extensions of the biphasic theory of Mow et al. [1980, ASME J. Biomech. Eng., 102, pp. 73–84] to incorporate tension–compression nonlinearity as well as intrinsic viscoelasticity of the solid matrix of cartilage. The biphasic-conewise linear elastic model proposed by Soltz and Ateshian [2000, ASME J. Biomech. Eng., 122, pp. 576–586] and based on the bimodular stress-strain constitutive law introduced by Curnier et al. [1995, J. Elasticity, 37, pp. 1–38], as well as the biphasic poroviscoelastic model of Mak [1986, ASME J. Biomech. Eng., 108, pp. 123–130], which employs the quasi-linear viscoelastic model of Fung [1981, Biomechanics: Mechanical Properties of Living Tissues, Springer-Verlag, New York], were combined in a single model to analyze the response of cartilage to standard testing configurations. Results were compared to experimental data from the literature and it was found that a simultaneous prediction of compression and tension experiments of articular cartilage, under stress-relaxation and dynamic loading, can be achieved when properly taking into account both flow-dependent and flow-independent viscoelasticity effects, as well as tension–compression nonlinearity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Moutos, F. T., Freed, L. E., & Guilak, F. (2007) · Nature Materials · doi:10.1038/nmat1822 · Cited by 738
Mechano-Electrochemical Properties Of Articular Cartilage: Their Inhomogeneities and Anisotropies
Mow, V. C., & Guo, X. E. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.110701.120309 · Cited by 478
Self-citationLiao, I., Moutos, F. T., Estes, B. T., Zhao, X., & Guilak, F. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201300483 · Cited by 276
Dowson, D. (2012) · Faraday Discussions · doi:10.1039/c2fd20103h · Cited by 111
Computational aspects in mechanical modeling of the articular cartilage tissue
Mohammadi, H., Mequanint, K., & Herzog, W. (2013) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/0954411912470239 · Cited by 28
Metadata
- Authors
- Huang, C.-Y., Mow, V. C., & Ateshian, G. A.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2001-05-16
- Volume
- 123
- Issue
- 5
- Pages
- 410-417
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2036924146
- Cited by
- 229
- References
- 0
- FWCI
- 7.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Role of Flow-Independent Viscoelasticity in the Biphasic Tensile and Compressive Responses of Articular Cartilage. https://app.cochat.ai/papers/10.1115/1.1392316
- The paper
- Huang, C.-Y., Mow, V. C., & Ateshian, G. A. (2001). The Role of Flow-Independent Viscoelasticity in the Biphasic Tensile and Compressive Responses of Articular Cartilage. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1392316
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.