Fluid Shear Stress-Induced Alignment of Cultured Vascular Smooth Muscle Cells
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
The study objectives were to quantify the time- and magnitude-dependence of flow-induced alignment in vascular smooth muscle cells (SMC) and to identify pathways related to the orientation process. Using an intensity gradient method, we demonstrated that SMC aligned in the direction perpendicular to applied shear stress, which contrasts with parallel alignment of endothelial cells under flow. SMC alignment varied with the magnitude of and exposure time to shear stress and is a continuous process that is dependent on calcium and cycloskeleton based mechanisms. A clear understanding and control of flow-induced SMC alignment will have implications for vascular tissue engineering.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Malek, A. M., & Izumo, S. (1996) · Journal of Cell Science · doi:10.1242/jcs.109.4.713 · Cited by 531
Cited by
Small-diameter vascular tissue engineering
Seifu, D. G., Purnama, A., Mequanint, K., & Mantovani, D. (2013) · Nature Reviews Cardiology · doi:10.1038/nrcardio.2013.77 · Cited by 501
Interstitial fluid flow induces myofibroblast differentiation and collagen alignment in vitro
Ng, C. P., Hinz, B., & Swartz, M. A. (2005) · Journal of Cell Science · doi:10.1242/jcs.02605 · Cited by 360
Butcher, J. T., Penrod, A. M., García, A. J., & Nerem, R. M. (2004) · Arteriosclerosis, Thrombosis, and Vascular Biology · doi:10.1161/01.atv.0000130462.50769.5a · Cited by 295
Mechanical, biochemical, and extracellular matrix effects on vascular smooth muscle cell phenotype
Stegemann, J. P., Hong, H., & Nerem, R. M. (2005) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01114.2004 · Cited by 291
Engineering cell alignment in vitro
Li, Y., Huang, G., Zhang, X., Wang, L., Du, Y., Lu, T. J., & Xu, F. (2014) · Biotechnology Advances · doi:10.1016/j.biotechadv.2013.11.007 · Cited by 272
Metadata
- Authors
- Lee, A. A., Graham, D. A., Dela Cruz, S., Ratcliffe, A., & Karlon, W. J.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2001-10-02
- Volume
- 124
- Issue
- 1
- Pages
- 37-43
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2080731079
- Cited by
- 108
- References
- 1
- FWCI
- 1.62
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluid Shear Stress-Induced Alignment of Cultured Vascular Smooth Muscle Cells. https://app.cochat.ai/papers/10.1115/1.1427697
- The paper
- Lee, A. A., Graham, D. A., Dela Cruz, S., Ratcliffe, A., & Karlon, W. J. (2002). Fluid Shear Stress-Induced Alignment of Cultured Vascular Smooth Muscle Cells. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.1427697
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.