The DOI matches its Crossref record.
Mechanical Properties of Tendons: Changes With Sterilization and Preservation
Abstract
Tendon allografts are commonly used to replace damaged anterior cruciate ligaments (ACL). Some of the sterilization and preservation techniques used by tissue banks with tendon allografts are thought to impair the mechanical properties of graft tissues. The tensile mechanical properties of porcine toe extensor tendons were measured using a dynamic testing machine following either freezing, freeze-drying, freezing then irradiation at 25 kGy (2.5 MRad), freeze-drying then irradiation, or freeze-drying then ethylene oxide gas sterilization. There was a small but significant difference in Young’s modulus between the frozen group (0.88 GPa ± 0.09 SD) and both the fresh group (0.98 GPa ± 0.12 SD) and the frozen irradiated group (0.97 GPa ± 0.08 SD). No values of Young’s modulus were obtained for the freeze-dried irradiated tendons. The ultimate tensile stress (UTS) of the freeze-dried irradiated group (4.7 MPa ± 4.8 SD) was significantly different from both the fresh and the frozen irradiated groups, being reduced by approximately 90 percent. There were no significant changes in UTS or Young’s modulus between any of the other groups. If irradiation is to be used to sterilize a tendon replacement for an ACL it must take place after freeze-drying to maintain mechanical properties.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Reprint of: Extracellular matrix as a biological scaffold material: Structure and function
Badylak, S. F., Freytes, D. O., & Gilbert, T. W. (2015) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.07.016 · Cited by 1,362
Current Trends in Anterior Cruciate Ligament Reconstruction
Fu, F. H., Bennett, C. H., Lattermann, C., & Ma, C. B. (1999) · The American Journal of Sports Medicine · doi:10.1177/03635465990270062501 · Cited by 564
In vivo human tendon mechanical properties
Maganaris, C. N., & Paul, J. P. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.00307.x · Cited by 494
Mechanical properties of the human achilles tendon
Wren, T. A. L., Yerby, S. A., Beaupré, G. S., & Carter, D. R. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00089-9 · Cited by 466
Measuring elasticity of biological materials by atomic force microscopy
Vinckier, A., & Semenza, G. (1998) · FEBS Letters · doi:10.1016/s0014-5793(98)00592-4 · Cited by 386
Metadata
- Authors
- Smith, C. W., Young, I. S., & Kearney, J. N.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1996-02-01
- Volume
- 118
- Issue
- 1
- Pages
- 56-61
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2151174378
- Cited by
- 158
- References
- 0
- FWCI
- 4.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mechanical Properties of Tendons: Changes With Sterilization and Preservation. https://app.cochat.ai/papers/10.1115/1.2795946
- The paper
- Smith, C. W., Young, I. S., & Kearney, J. N. (1996). Mechanical Properties of Tendons: Changes With Sterilization and Preservation. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2795946
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.