The DOI matches its Crossref record.
A Three-Dimensional Finite Element Method for Large Elastic Deformations of Ventricular Myocardium: II—Prolate Spheroidal Coordinates
Abstract
A three-dimensional finite element method for nonlinear finite elasticity is presented using prolate spheroidal coordinates. For a thick-walled ellipsoidal model of passive anisotropic left ventricle, a high-order (cubic Hermite) mesh with 3 elements gave accurate continuous stresses and strains, with a 69 percent savings in degrees of freedom (dof) versus a 70-element standard low-order model. A custom mixed-order model offered 55 percent savings in dof and 39 percent savings in solution time compared with the low-order model. A nonsymmetric 3D model of the passive canine LV was solved using 16 high-order elements. Continuous nonhomogeneous stresses and strains were obtained within 1 hour on a laboratory workstation, with an estimated solution time of less than 4 hours to model end-systole. This method represents the first practical opportunity to solve large-scale anatomically detailed models for cardiac stress analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Holzapfel, G. A., & Ogden, R. W. (2009) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2009.0091 · Cited by 836
Wall, S. T., Walker, J. C., Healy, K. E., Ratcliffe, M. B., & Guccione, J. M. (2006) · Circulation · doi:10.1161/circulationaha.106.657270 · Cited by 312
Self-citationKohl, P., Hunter, P., & Noble, D. (1999) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(98)00038-8 · Cited by 293
Self-citationHyperelastic Energy Densities for Soft Biological Tissues: A Review
Chagnon, G., Rebouah, M., & Favier, D. (2015) · Journal of Elasticity · doi:10.1007/s10659-014-9508-z · Cited by 292
Three-dimensional analysis of regional cardiac function: a model of rabbit ventricular anatomy
Vetter, F. J., & McCulloch, A. D. (1998) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(98)00006-6 · Cited by 255
Self-citation
Metadata
- Authors
- Costa, K. D., Hunter, P. J., Wayne, J. S., Waldman, L. K., Guccione, J. M., & McCulloch, A. D.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1996-11-01
- Volume
- 118
- Issue
- 4
- Pages
- 464-472
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2044609101
- Cited by
- 172
- References
- 0
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A Three-Dimensional Finite Element Method for Large Elastic Deformations of Ventricular Myocardium: II—Prolate Spheroidal Coordinates. https://app.cochat.ai/papers/10.1115/1.2796032
- The paper
- Costa, K. D., Hunter, P. J., Wayne, J. S., Waldman, L. K., Guccione, J. M., & McCulloch, A. D. (1996). A Three-Dimensional Finite Element Method for Large Elastic Deformations of Ventricular Myocardium: II—Prolate Spheroidal Coordinates. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2796032
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.