Numerical Model of Fluid Flow and Oxygen Transport in a Radial-Flow Microchannel Containing Hepatocytes
The DOI matches its Crossref record.
Abstract
The incorporation of monolayers of cultured hepatocytes into an extracorporeal perfusion system has become a promising approach for the development of a temporary bioartificial liver (BAL) support system. In this paper we present a numerical investigation of the oxygen tension, shear stress, and pressure drop in a bioreactor for a BAL composed of plasma-perfused chambers containing monolayers of porcine hepatocytes. The chambers consist of microfabricated parallel disks with center-to-edge radial flow. The oxygen uptake rate (OUR), measured in vitro for porcine hepatocytes, was curve-fitted using Michaelis–Menten kinetics for simulation of the oxygen concentration profile. The effect of different parameters that may influence the oxygen transport inside the chambers, such as the plasma flow rate, the chamber height, the initial oxygen tension in the perfused plasma, the OUR, and Km was investigated. We found that both the plasma flow rate and the initial oxygen tension may have an important effect upon oxygen transport. Increasing the flow rate and/or the inlet oxygen tension resulted in improved oxygen transport to cells in the radial-flow microchannels, and allowed significantly greater diameter reactor without oxygen limitation to the hepatocytes. In the range investigated in this paper (10 μm < H < 100 μm), and for a constant plasma flow rate, the chamber height, H, had a negligible effect on the oxygen transport to hepatocytes. On the contrary, it strongly affected the mechanical stress on the cells that is also crucial for the successful design of the BAL reactors. A twofold decrease in chamber height from 50 to 25 μm produced approximately a fivefold increase in maximal shear stress at the inlet of the reactor from 2 to 10 dyn/cm2. Further decrease in chamber height resulted in shear stress values that are physiologically unrealistic. Therefore, the channel height needs to be carefully chosen in a BAL design to avoid deleterious hydrodynamic effects on hepatocytes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Computerized microfluidic cell culture using elastomeric channels and Braille displays
Gu, W., Zhu, X., Futai, N., Cho, B. S., & Takayama, S. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404353101 · Cited by 403
Tilles, A. W., Baskaran, H., Roy, P., Yarmush, M. L., & Toner, M. (2001) · Biotechnology and Bioengineering · doi:10.1002/bit.1071 · Cited by 330
Self-citationFormation of steady‐state oxygen gradients in vitro: Application to liver zonation
Allen, J. W., & Bhatia, S. N. (2003) · Biotechnology and Bioengineering · doi:10.1002/bit.10569 · Cited by 269
Self-citationFunctional behavior of primary rat liver cells in a three-dimensional perfused microarray bioreactor
Powers, M. J., Janigian, D. M., Wack, K. E., Baker, C. S., Stolz, D. B., & Griffith, L. G. (2002) · Tissue Engineering · doi:10.1089/107632702760184745 · Cited by 234
“Several bioreactor systems that capture some aspects of in vivo physiology have been described for liver cell culture, ranging from flat-plate or matrix-sandwiched monolayer designs 2,3,36 to three-dimensional (3-”
A microfluidic hepatic coculture platform for cell-based drug metabolism studies
Novik, E., Maguire, T. J., Chao, P., Cheng, K. C., & Yarmush, M. L. (2010) · Biochemical Pharmacology · doi:10.1016/j.bcp.2009.11.010 · Cited by 212
“A fairly large number of prior studies have demonstrated the beneficial effects of flow on hepatocyte function [4–13].”
BackgroundSelf-citation
Metadata
- Authors
- Ledezma, G. A., Folch, A., Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1999-02-01
- Volume
- 121
- Issue
- 1
- Pages
- 58-64
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2085759532
- Cited by
- 57
- References
- 0
- FWCI
- 2.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Numerical Model of Fluid Flow and Oxygen Transport in a Radial-Flow Microchannel Containing Hepatocytes. https://app.cochat.ai/papers/10.1115/1.2798043
- The paper
- Ledezma, G. A., Folch, A., Bhatia, S. N., Balis, U. J., Yarmush, M. L., & Toner, M. (1999). Numerical Model of Fluid Flow and Oxygen Transport in a Radial-Flow Microchannel Containing Hepatocytes. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2798043
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.