The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Flow Boiling in Horizontal Tubes: Part 1—Development of a Diabatic Two-Phase Flow Pattern Map
Open accessAbstract
An improved two-phase flow pattern map is proposed for evaporation in horizontal tubes. The new map was developed based on flow pattern data for five different refrigerants covering a wide range of mass velocities and vapor qualities. The new map is valid for both adiabatic and diabatic (evaporating) flows and accurately identifies about 96 percent of the 702 data points. In addition, the new flow pattern map includes the prediction of the onset of dryout at the top of the tube during evaporation inside horizontal tubes as a function of heat flux and flow parameters.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A model for predicting flow regime transitions in horizontal and near horizontal gas‐liquid flow
Taitel, Y., & Dukler, A. E. (1976) · AIChE Journal · doi:10.1002/aic.690220105 · Cited by 2,915
95/03868 Convective boiling and condensation
(1995) · Fuel and Energy Abstracts · doi:10.1016/0140-6701(95)95486-o · Cited by 2,445
A general correlation for flow boiling in tubes and annuli
Gungor, K. E., & Winterton, R. H. S. (1986) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(86)90205-x · Cited by 1,275
Kandlikar, S. G. (1990) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2910348 · Cited by 1,191
Chart correlation for saturated boiling heat transfer: Equations and further study
Shah, M. M. (1982) · ASHRAE winter conference papers · Cited by 604
Simplified general correlation for saturated flow boiling and comparisons of correlations with data
Gungor, K., & Winterton, R. H. S. (1987) · Process Safety and Environmental Protection · Cited by 477
Cited by
Fundamental process and system design issues in CO2 vapor compression systems
Kim, M. (2004) · Progress in Energy and Combustion Science · doi:10.1016/j.pecs.2003.09.002 · Cited by 735
Condensation in horizontal tubes, part 2: new heat transfer model based on flow regimes
Thome, J. R., El Hajal, J., & Cavallini, A. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00140-6 · Cited by 592
Self-citationCondensation in horizontal tubes, part 1: two-phase flow pattern map
El Hajal, J., Thome, J. R., & Cavallini, A. (2003) · International Journal of Heat and Mass Transfer · doi:10.1016/s0017-9310(03)00139-x · Cited by 537
Self-citationInvestigation of flow boiling in horizontal tubes: Part I—A new diabatic two-phase flow pattern map
Wojtan, L., Ursenbacher, T., & Thome, J. R. (2005) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.12.012 · Cited by 529
Self-citationOng, C. L., & Thome, J. R. (2011) · Experimental Thermal and Fluid Science · doi:10.1016/j.expthermflusci.2010.08.004 · Cited by 365
Self-citation
Metadata
- Authors
- Kattan, N., Thome, J. R., & Favrat, D.
- Venue
- Journal of Heat Transfer
- Publisher
- ASME International
- Published
- 1998-02-01
- Volume
- 120
- Issue
- 1
- Pages
- 140-147
- ISSN
- 0022-1481 (ISSN-L)
- 1528-8943
- OpenAlex
- W2059484951
- Cited by
- 483
- References
- 6
- FWCI
- 20.74
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.