The DOI matches its Crossref record.
Engineered Alignment in Media Equivalents: Magnetic Prealignment and Mandrel Compaction
Abstract
We predicted and measured the evolution of smooth muscle cell (SMC) orientation in media-equivalents (MEs) for four fabrication conditions (F−, M−, F+, M+) under Free or Mandrel compaction (F/M) with and without magnetic prealignment of the collagen fibrils in the circumferential direction (±). Mandrel compaction refers to SMC-induced compaction of the ME that is constrained by having a nonadhesive mandrel placed in the ME lumen. Predictions were made using our anisotropic biphasic theory (ABT) for tissue-equivalent mechanics. Successful prediction of trends of the SMC orientation data for all four fabrication cases was obtained: maintenance of the initial isotropic state for F−, loss of initial circumferential alignment for F+, development of circumferential alignment for M−, and enhancement of initial circumferential alignment for M+. These results suggest two mechanisms by which the presence of the mandrel leads to much greater mechanical stiffness in the circumferential direction reported for mandrel compacted MEs relative to free compacted MEs: (1) by inducing an increasing circumferential alignment of the SMC and collagen, and (2) by inducing a large stress on the SMC, resulting in secretion and accumulation of stiffening components.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The Tissue-Engineered Vascular Graft—Past, Present, and Future
Pashneh-Tala, S., MacNeil, S., & Claeyssens, F. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0100 · Cited by 798
Dynamic Mechanical Conditioning of Collagen-Gel Blood Vessel Constructs Induces Remodeling In Vitro
Seliktar, D., Black, R. A., Vito, R. P., & Nerem, R. M. (2000) · Annals of Biomedical Engineering · doi:10.1114/1.275 · Cited by 555
Small-Diameter Artificial Arteries Engineered In Vitro
Isenberg, B. C., Williams, C., & Tranquillo, R. T. (2006) · Circulation Research · doi:10.1161/01.res.0000196867.12470.84 · Cited by 469
Self-citationNerem, R. M., & Seliktar, D. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.225 · Cited by 466
Vaz, C. M., van Tuijl, S., Bouten, C. V. C., & Baaijens, F. P. T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2005.06.006 · Cited by 459
Metadata
- Authors
- Barocas, V. H., Girton, T. S., & Tranquillo, R. T.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1998-10-01
- Volume
- 120
- Issue
- 5
- Pages
- 660-666
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2070679280
- Cited by
- 164
- References
- 0
- FWCI
- 3.70
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Engineered Alignment in Media Equivalents: Magnetic Prealignment and Mandrel Compaction. https://app.cochat.ai/papers/10.1115/1.2834759
- The paper
- Barocas, V. H., Girton, T. S., & Tranquillo, R. T. (1998). Engineered Alignment in Media Equivalents: Magnetic Prealignment and Mandrel Compaction. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2834759
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.