An Evaluation of the Weinbaum-Jiji Bioheat Equation for Normal and Hyperthermic Conditions
The DOI matches its Crossref record.
Abstract
The predictions of the simplified Weinbaum-Jiji (WJ) bioheat transfer equation in one dimension are compared to those of the complete one-dimensional three-equation model that represented the starting point for the derivation of the WJ equation, as well as results obtained using the traditional bioheat transfer equation of Pennes [6]. The WJ equation provides very good agreement with the three-equation model for vascular generations 2 to 9, which are located in the outer half of the muscle layer, where the paired vessel diameters are less than 500 μm, under basal blood flow conditions. At the same time, the Pennes equation yields a better description of heat transfer in the first generation, where the vessels’ diameters are greater than 500 μm and ε, the vessels’ normalized thermal equilibration length, is greater than 0.3. These results were obtained under both normothermic and hyperthermic conditions. A new conceptual view of the blood source term in the Pennes equation has emerged from these results. This source term, which was originally intended to represent an isotropic heat source in the capillaries, is shown to describe instead the heat transfer from the largest countercurrent microvessels to the tissue due to small vessel bleed-off. The WJ equation includes this effect, but significantly overestimates the second type of tissue heat transfer, countercurrent convective heat transfer, when ε > 0.3. Indications are that a “hybrid” model that applies the Pennes equation in the first generation (normothermic) and first two to three generations (after onset of hyperthermia) and the Weinbaum-Jiji equation in the subsequent generations would be most appropriate for simulations of bioheat transfer in perfused tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fiala, D., Lomas, K. J., & Stohrer, M. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1957 · Cited by 849
Recent developments in modeling heat transfer in blood perfused tissues
Arkin, H., Xu, L. X., & Holmes, K. R. (1994) · IEEE Transactions on Biomedical Engineering · doi:10.1109/10.284920 · Cited by 431
Thermal Indices and Thermophysiological Modeling for Heat Stress
Havenith, G., & Fiala, D. (2015) · Comprehensive Physiology · doi:10.1002/cphy.c140051 · Cited by 262
“However, Pennes’ traditional bioheat equation has become the preferred approach in whole body models due to its simplicity and accuracy that is comparable with more detailed models requiring comprehensive data on the vascular architecture of tissues (3,27).”
Mathematical models of bioheat transfer
Charny, C. K. (1992) · Advances in heat transfer · doi:10.1016/s0065-2717(08)70344-7 · Cited by 241
Self-citation
Metadata
- Authors
- Charny, C. K., Weinbaum, S., & Levin, R. L.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1990-02-01
- Volume
- 112
- Issue
- 1
- Pages
- 80-87
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2031091093
- Cited by
- 71
- References
- 0
- FWCI
- 1.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: An Evaluation of the Weinbaum-Jiji Bioheat Equation for Normal and Hyperthermic Conditions. https://app.cochat.ai/papers/10.1115/1.2891130
- The paper
- Charny, C. K., Weinbaum, S., & Levin, R. L. (1990). An Evaluation of the Weinbaum-Jiji Bioheat Equation for Normal and Hyperthermic Conditions. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2891130
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.