Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis
The DOI matches its Crossref record.
Abstract
In Part I we reported the results of linear finite element models of the proximal femur generated using geometric and constitutive data collected with quantitative computed tomography. These models demonstrated excellent agreement with in vitro studies when used to predict ultimate failure loads. In Part II, we report our extension of those finite element models to include nonlinear behavior of the trabecular and cortical bone. A highly nonlinear material law, originally designed for representing concrete, was used for trabecular bone, while a bilinear material law was used for cortical bone. We found excellent agreement between the model predictions and in vitro fracture data for both the onset of bone yielding and bone fracture. For bone yielding, the model predictions were within 2 percent for a load which simulated one-legged stance and 1 percent for a load which simulated a fall. For bone fracture, the model predictions were within 1 percent and 17 percent, respectively. The models also demonstrated different fracture mechanisms for the two different loading configurations. For one-legged stance, failure within the primary compressive trabeculae at the subcapital region occurred first, leading to load transfer and, ultimately, failure of the surrounding cortical shell. However, for a fall, failure of the cortical and trabecular bone occurred simultaneously within the intertrochanteric region. These results support our previous findings that the strength of the subcapital region is primarily due to trabecular bone whereas the strength of the intertrochanteric region is primarily due to cortical bone.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Modelling bone tissue fracture and healing: a review
Doblaré, M., Garcı́a, J. M., & Gómez, M. J. (2004) · Engineering Fracture Mechanics · doi:10.1016/j.engfracmech.2003.08.003 · Cited by 504
“This is usually accurate enough, but some authors obtain more accurate results by considering nonlinear material properties for cortical and trabecular bone [49,50].”
BackgroundNiebur, G. L., Feldstein, M. J., Yuen, J. C., Chen, T. J., & Keaveny, T. M. (2000) · Journal of Biomechanics · doi:10.1016/s0021-9290(00)00149-4 · Cited by 431
Systematic and random errors in compression testing of trabecular bone
Keaveny, T. M., Pinilla, T. P., Crawford, R. P., Kopperdahl, D. L., & Lou, A. (1997) · Journal of Orthopaedic Research · doi:10.1002/jor.1100150115 · Cited by 377
Schileo, E., Taddei, F., Cristofolini, L., & Viceconti, M. (2008) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2007.09.009 · Cited by 373
Metadata
- Authors
- Lotz, J. C., Cheal, E. J., & Hayes, W. C.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1991-11-01
- Volume
- 113
- Issue
- 4
- Pages
- 361-365
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W4237522513
- Cited by
- 115
- References
- 0
- FWCI
- 0.45
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis. https://app.cochat.ai/papers/10.1115/1.2895413
- The paper
- Lotz, J. C., Cheal, E. J., & Hayes, W. C. (1991). Fracture Prediction for the Proximal Femur Using Finite Element Models: Part II—Nonlinear Analysis. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2895413
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.