Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 243

The DOI matches its Crossref record.

Mechanical and Electrical Responses of the Squid Giant Axon to Simple Elongation

Galbraith, J. A., Thibault, L. E., Matteson, D. R. · 1993 · Journal of Biomechanical Engineering

Abstract

There is a limited amount of information available on the mechanical and functional response of the nervous system to loading. While deformation of cerebral, spinal, or peripheral nerve tissue can have particularly severe consequences, most research in this area has concentrated on either demonstrating in-vivo functional changes and disclosing the effected anatomical pathways, or describing material deformations of the composite structure. Although such studies have successfully produced repeatable traumas, they have not addressed the mechanisms of these mechanically induced injuries. Therefore, a single cell model is required in order to gain further understanding of this complex phenomena. An isolated squid giant axon was subjected to controlled uniaxial loading and its mechanical and physiological responses were monitored with an instrument specifically designed for these experiments. These results determined that the mechanical properties of the isolated axon are similar to those of other soft tissues, and include features such as a nonlinear load-deflection curve and a hysteresis loop upon unloading. The mechanical response was modeled with the quasi-linear viscoelastic theory (Fung, 1972). The physiological response of the axon to quasi-static loading was a small reversible hyperpolarization; however, as the rate of loading was increased, the axon depolarized and the magnitude and the time needed to recover to the original resting potential increased in a nonlinear fashion. At elongations greater than twenty percent an irreversible injury occurs and the membrane potential does not completely recover to baseline.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.2895464

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 243

Metadata

Authors
Galbraith, J. A., Thibault, L. E., & Matteson, D. R.
Venue
Journal of Biomechanical Engineering
Published
1993-02-01
Volume
115
Issue
1
Pages
13-22
ISSN
  • 0148-0731 (ISSN-L)
  • 1528-8951
OpenAlex
W1997831000
Cited by
243
References
0
FWCI
3.24
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical and Electrical Responses of the Squid Giant Axon to Simple Elongation. https://app.cochat.ai/papers/10.1115/1.2895464
The paper
Galbraith, J. A., Thibault, L. E., & Matteson, D. R. (1993). Mechanical and Electrical Responses of the Squid Giant Axon to Simple Elongation. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2895464

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.