The DOI matches its Crossref record.
Effects of Stress Shielding on the Mechanical Properties of Rabbit Patellar Tendon
Abstract
Mechanical properties of the stress-shielded patellar tendon were studied in the rabbit knee. Stress shielding was accomplished by stretching a stainless-steel wire installed between the patella and tibial tubercle and thus, releasing the tension in the patellar tendon completely. Tensile tests were carried out on the specimens obtained from the patellar tendons which were exposed to the stress shielding for 1 to 6 weeks. The stress shielding changed the mechanical properties of the patellar tendon significantly: it decreased the tangent modulus and tensile strength to 9 percent of the control values after 3 weeks. There was a 131 percent increase in the cross-sectional area and a 15 percent decrease in the tendinous length. Remarkable changes were also observed in the structural properties: for example, the maximum load of the bone-tendon complex decreased to 20 percent of the control value after 3 weeks. Histological studies showed that the stress shielding increased the number of fibroblasts and decreased the longitudinally aligned collagen bundles. These results imply that if no stress is applied to the autograft in the case of augmentative reconstruction of the knee ligament, the graft strength decreases remarkably.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, J. H.-C. (2006) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2005.05.011 · Cited by 1,002
KRAUSHAAR, B. S., & NIRSCHL, R. P. (1999) · The Journal of Bone & Joint Surgery · doi:10.2106/00004623-199902000-00014 · Cited by 708
Mechanical properties of the human achilles tendon
Wren, T. A. L., Yerby, S. A., Beaupré, G. S., & Carter, D. R. (2001) · Clinical Biomechanics · doi:10.1016/s0268-0033(00)00089-9 · Cited by 466
Biomechanics of tendon injury and repair
Lin, T. W., Cardenas, L., & Soslowsky, L. J. (2004) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2003.11.005 · Cited by 461
Repair of patellar tendon injuries using a cell–collagen composite
Awad, H. A., Boivin, G. P., Dressler, M. R., Smith, F. N. L., Young, R. G., & Butler, D. L. (2003) · Journal of Orthopaedic Research · doi:10.1016/s0736-0266(02)00163-8 · Cited by 396
Calf muscle-tendon properties and postural balance in old age
Onambele, G. L., Narici, M. V., & Maganaris, C. N. (2006) · Journal of Applied Physiology · doi:10.1152/japplphysiol.01442.2005 · Cited by 353
Autologous blood injections for refractory lateral epicondylitis
Edwards, S. G., & Calandruccio, J. H. (2003) · The Journal of Hand Surgery · doi:10.1053/jhsu.2003.50041 · Cited by 338
Tomita, F., Yasuda, K., Mikami, S., Sakai, T., Yamazaki, S., & Tohyama, H. (2001) · Arthroscopy: The Journal of Arthroscopic & Related Surgery · doi:10.1053/jars.2001.24059 · Cited by 306
Self-citationThe Role of Mechanical Loading in Tendon Development, Maintenance, Injury, and Repair
Galloway, M. T., Lalley, A. L., & Shearn, J. T. (2013) · Journal of Bone and Joint Surgery · doi:10.2106/jbjs.l.01004 · Cited by 270
Biomechanical studies of the remodeling of knee joint tendons and ligaments
Hayashi, K. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(95)00163-8 · Cited by 78
Self-citation
Metadata
- Authors
- Yamamoto, N., Ohno, K., Hayashi, K., Kuriyama, H., Yasuda, K., & Kaneda, K.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1993-02-01
- Volume
- 115
- Issue
- 1
- Pages
- 23-28
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2061523780
- Cited by
- 161
- References
- 0
- FWCI
- 6.47
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.