The DOI matches its Crossref record.
Hemodynamics and the Vascular Endothelium
Abstract
The endothelium, once thought to be a passive, non-thrombogenic barrier, is now recognized as being a dynamic participant in vascular biology and pathobiology. Part of its dynamic nature is due to the influence of the mechanical environment imposed by the hemodynamics of the vascular system. Over the past two decades much has been learned about the influence of hemodynamics on the vascular endothelium. This has been in part through in vivo experiments; however, in the past 15 years a number of laboratories have turned to the application of in vitro cell culture systems to investigate the influence of flow and cyclic stretch on the biology of vascular endothelium. Taken together these studies demonstrate that flow and the associated shear stress modulate both endothelial cell structure and function. Cell culture studies employing cyclic stretch provide similar evidence. Furthermore, these effects of mechanical environment extend to the gene expression level, with there being a differential regulation of mRNA. A critical question is how does an endothelial cell recognize the mechanical environment in which it resides and, having done so, how is this transduced into the changes in structure and function observed? Although our knowledge of the recognition events remains limited, studies on signal transduction in response to a mechanical stimulus indicate that many of the second messengers known to be triggered by chemical agonists also are involved in transducing a mechanical signal. Over the past 20 years our understanding of the importance of the influence of the mechanical environment imposed by the hemodynamics of the system on vascular endothelial biology, both in the regulation of the normal biology of blood vessels and as a determinant of the distribution and development of atherosclerotic lesions, has grown immensely; however, there is still much to be learned.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Molecular basis of the effects of shear stress on vascular endothelial cells
Li, Y.-S. J., Haga, J. H., & Chien, S. (2005) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2004.09.030 · Cited by 904
Mechanotransduction and endothelial cell homeostasis: the wisdom of the cell
Chien, S. (2007) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.01047.2006 · Cited by 907
Oxidative Stress as a Regulator of Gene Expression in the Vasculature
Kunsch, C., & Medford, R. M. (1999) · Circulation Research · doi:10.1161/01.res.85.8.753 · Cited by 799
Nitric Oxide Synthesis by Cultured Endothelial Cells Is Modulated by Flow Conditions
Noris, M., Morigi, M., Donadelli, R., Aiello, S., Foppolo, M., Todeschini, M., Orisio, S., Remuzzi, G., & Remuzzi, A. (1995) · Circulation Research · doi:10.1161/01.res.76.4.536 · Cited by 543
Berger, S. A., & Jou, L.-D. (2000) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.32.1.347 · Cited by 502
Metadata
- Authors
- Nerem, R. M.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1993-11-01
- Volume
- 115
- Issue
- 4B
- Pages
- 510-514
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2060034892
- Cited by
- 162
- References
- 0
- FWCI
- 1.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Hemodynamics and the Vascular Endothelium. https://app.cochat.ai/papers/10.1115/1.2895532
- The paper
- Nerem, R. M. (1993). Hemodynamics and the Vascular Endothelium. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2895532
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.