The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis
Abstract
Fluid dynamics research over the past twenty years has contributed immensely to our knowledge of atherosclerosis. The ability to detect localized atherosclerotic plaques using noninvasive ultrasonic methods was advanced significantly by investigations into the nature and occurrence of velocity disturbances created by arterial stenoses, and diagnosis of carotid bifurcation disease using a combination of ultrasonic imaging and Doppler measurement of blood velocity is now quite routine. Since atherosclerotic plaques tend to be localized at sites of branching and artery curvature and since these locations would be expected to harbor complex flow patterns, investigators postulated that fluid dynamics might play an initiating role in atherogenesis. Several fluid dynamic variables were proposed as initiating factors. Investigations were undertaken during the 1980s in which fluid dynamic model experiments with physiologic geometries and flow conditions were employed to simulate arterial flows and in which morphometric mapping of intimal thickness was performed in human arteries. Correlations between fluid dynamic variables and intimal thickness revealed that atherosclerotic plaques tended to occur at sites of low and oscillating wall shear stress; and these observations were reinforced by studies in a monkey model of atherosclerosis. Concomitantly, it was realized that arteries adapt their diameters so as to maintain wall shear stress in a narrow range of values around 15 dynes/cm2, findings which were based both on observations of normal arteries and on animal studies in which flow rates were manipulated and arterial diameter adaptation was measured. Currently, a working hypothesis for the role of fluid dynamics in atherogenesis is that intimal thickening is a normal response to low wall shear stress, and this intimal thickening can develop into an early atherosclerotic plaque under certain circumstances such as excessive low density lipoprotein concentrations in blood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Chiu, J.-J., & Chien, S. (2011) · Physiological Reviews · doi:10.1152/physrev.00047.2009 · Cited by 2,280
Endothelial Dysfunction, Hemodynamic Forces, and Atherogenesisa
GIMBRONE, M. A., TOPPER, J. N., NAGEL, T., ANDERSON, K. R., & GARCIA‐CARDEÑA, G. (2000) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.2000.tb06318.x · Cited by 836
Kuhlencordt, P. J., Gyurko, R., Han, F., Scherrer-Crosbie, M., Aretz, T. H., Hajjar, R., Picard, M. H., & Huang, P. L. (2001) · Circulation · doi:10.1161/hc2901.091399 · Cited by 630
Fluid shear stress and the vascular endothelium: for better and for worse
Resnick, N., Yahav, H., Shay-Salit, A., Shushy, M., Schubert, S., Zilberman, L. C. M., & Wofovitz, E. (2003) · Progress in Biophysics and Molecular Biology · doi:10.1016/s0079-6107(02)00052-4 · Cited by 577
Nitric Oxide Synthesis by Cultured Endothelial Cells Is Modulated by Flow Conditions
Noris, M., Morigi, M., Donadelli, R., Aiello, S., Foppolo, M., Todeschini, M., Orisio, S., Remuzzi, G., & Remuzzi, A. (1995) · Circulation Research · doi:10.1161/01.res.76.4.536 · Cited by 543
Metadata
- Authors
- Giddens, D. P., Zarins, C. K., & Glagov, S.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1993-11-01
- Volume
- 115
- Issue
- 4B
- Pages
- 588-594
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2062747807
- Cited by
- 490
- References
- 0
- FWCI
- 4.86
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis. https://app.cochat.ai/papers/10.1115/1.2895545
- The paper
- Giddens, D. P., Zarins, C. K., & Glagov, S. (1993). The Role of Fluid Mechanics in the Localization and Detection of Atherosclerosis. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.2895545
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.