This paper describes recent published design advances that have been made in desiccant cooling systems. In desiccant cooling cycles, the desiccant reduces the humidity of the air by removing moisture from the air. Then the temperature is reduced by other components such as heat exchangers, evaporative coolers, or conventional cooling coils. The main advantage that desiccant cooling systems offer is the capability of using low-grade thermal energy. Desiccant cooling systems for residential and commercial applications are now being used to reduce energy-operating costs. However, the initial costs are comparatively high. The focus of research for the past decade has been to develop desiccant systems with a high coefficient of performance. Recent studies have emphasized computer modeling and hybrid systems that combine desiccant dehumidifiers with conventional systems.

Overview

Integrity signals

Registry

Crossref · 10.1115/1.2905965

Cites

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Absorption cooling systems use eco-friendly fluids including air and water, which have no negative impact on the environment.

    “The system uses eco-friendly fluids including air and water, which have no negative impact on the environment.”
  • Absorption cooling systems could operate with diverse thermal energy sources, even low-grade resources, in the regenerators.

    “It could operate with diverse thermal energy sources, even lowgrade resources, in the regenerators.”
  • Desiccant cooling systems work near atmospheric pressure, which makes them easy to construct, install, preserve and maintain.

    “Finally, the desiccant cooling system works near atmospheric pressure, which makes them easy to construct, install, preserve and maintain.”
  • The required electrical energy for absorption cooling can be less than 25% of conventional refrigeration systems, and this technique acts as an energy-efficient method, especially for hot dry and hot humid areas.

    “The required electrical energy can be less than 25 % of conventional refrigeration systems and this technique acts as an energy-efficient method, especially for hot dry and hot humid areas.”

Citations

Cited by

Sorted by citations

Metadata

Authors
Waugaman, D. G., Kini, A., & Kettleborough, C. F.
Affiliations
Texas A&M University (US)
Venue
Journal of Energy Resources Technology
Publisher
Wiley
Published
1993-03-01
Volume
115
Issue
1
Pages
1-8
ISSN
  • 0195-0738 (ISSN-L)
  • 1528-8994
OpenAlex
W2038036331
Cited by
158
References
0
Citations by year
2025: 4 · 2024: 1 · 2023: 4 · 2022: 2 · 2021: 7 · 2020: 8 · 2019: 7 · 2018: 8 · 2017: 5 · 2016: 10 · 2015: 5 · 2014: 8 · 2013: 12 · 2012: 7
FWCI
2.20
Type
journal article
Language
en
Open access
closed
Locations
Journal of Energy Resources Technology (publishedVersion)
Topics
  • Physical Sciences › Engineering › Mechanical Engineering › Adsorption and Cooling Systems
  • Physical Sciences › Engineering › Mechanical Engineering › Refrigeration and Air Conditioning Technologies
  • Physical Sciences › Engineering › Building and Construction › Building Energy and Comfort Optimization
Keywords
desiccant cooling systems, desiccant dehumidifier, low-grade thermal energy, coefficient of performance, evaporative coolers, heat exchangers, air dehumidification, energy cost reduction

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review