Three-Dimensional Computational Modeling of Subject-Specific Cerebrospinal Fluid Flow in the Subarachnoid Space
Open accessThe DOI matches its Crossref record.
Abstract
This study aims at investigating three-dimensional subject-specific cerebrospinal fluid (CSF) dynamics in the inferior cranial space, the superior spinal subarachnoid space (SAS), and the fourth cerebral ventricle using a combination of a finite-volume computational fluid dynamics (CFD) approach and magnetic resonance imaging (MRI) experiments. An anatomically accurate 3D model of the entire SAS of a healthy volunteer was reconstructed from high resolution T2 weighted MRI data. Subject-specific pulsatile velocity boundary conditions were imposed at planes in the pontine cistern, cerebellomedullary cistern, and in the spinal subarachnoid space. Velocimetric MRI was used to measure the velocity field at these boundaries. A constant pressure boundary condition was imposed at the interface between the aqueduct of Sylvius and the fourth ventricle. The morphology of the SAS with its complex trabecula structures was taken into account through a novel porous media model with anisotropic permeability. The governing equations were solved using finite-volume CFD. We observed a total pressure variation from −42Pato40Pa within one cardiac cycle in the investigated domain. Maximum CSF velocities of about 15cm∕s occurred in the inferior section of the aqueduct, 14cm∕s in the left foramen of Luschka, and 9cm∕s in the foramen of Magendie. Flow velocities in the right foramen of Luschka were found to be significantly lower than in the left, indicating three-dimensional brain asymmetries. The flow in the cerebellomedullary cistern was found to be relatively diffusive with a peak Reynolds number (Re)=72, while the flow in the pontine cistern was primarily convective with a peak Re=386. The net volumetric flow rate in the spinal canal was found to be negligible despite CSF oscillation with substantial amplitude with a maximum volumetric flow rate of 109ml∕min. The observed transient flow patterns indicate a compliant behavior of the cranial subarachnoid space. Still, the estimated deformations were small owing to the large parenchymal surface. We have integrated anatomic and velocimetric MRI data with computational fluid dynamics incorporating the porous SAS morphology for the subject-specific reconstruction of cerebrospinal fluid flow in the subarachnoid space. This model can be used as a basis for the development of computational tools, e.g., for the optimization of intrathecal drug delivery and computer-aided evaluation of cerebral pathologies such as syrinx development in syringomelia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fate of nanoparticles in the central nervous system after intrathecal injection in healthy mice
Householder, K. T., Dharmaraj, S., Sandberg, D. I., Wechsler-Reya, R. J., & Sirianni, R. W. (2019) · Scientific Reports · doi:10.1038/s41598-019-49028-w · Cited by 83
Elbert, D. L., Patterson, B. W., Lucey, B. P., Benzinger, T. L. S., & Bateman, R. J. (2022) · Communications Biology · doi:10.1038/s42003-022-03037-0 · Cited by 53
Metadata
- Authors
- Gupta, S., Soellinger, M., Boesiger, P., Poulikakos, D., & Kurtcuoglu, V.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2008-12-10
- Volume
- 131
- Issue
- 2
- Pages
- 021010-021010
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2152734721
- Cited by
- 131
- References
- 0
- FWCI
- 2.46
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.