The DOI matches its Crossref record.
The Application of a Homogeneous Half-Space Model in the Analysis of Endothelial Cell Micropipette Measurements
Abstract
Experimental studies have shown that endothelial cells which have been exposed to shear stress maintain a flattened and elongated shape after detachment. Their mechanical properties, which are studied using the micropipette experiments, are influenced by the level as well as the duration of the shear stress. In the present paper, we analyze these mechanical properties with the aid of two mathematical models suggested by the micropipette technique and by the geometry peculiar to these cells in their detached post-exposure state. The two models differ in their treatment of the contact zone between the cell and the micropipette. The main results are expressions for an effective Young’s modulus for the cells, which are used in conjunction with the micropipette data to determine an effective Young’s modulus for bovine endothelial cells, and to discuss the dependence of this modulus upon exposure to shear stress.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Cell prestress. I. Stiffness and prestress are closely associated in adherent contractile cells
Wang, N., Tolić-Nørrelykke, I. M., Chen, J., Mijailovich, S. M., Butler, J. P., Fredberg, J. J., & Stamenović, D. (2002) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.00269.2001 · Cited by 669
Viscoelastic Properties of the Cell Nucleus
Guilak, F., Tedrow, J. R., & Burgkart, R. (2000) · Biochemical and Biophysical Research Communications · doi:10.1006/bbrc.2000.2360 · Cited by 587
Human cardiac organoids for the modelling of myocardial infarction and drug cardiotoxicity
Richards, D. J., Li, Y., Kerr, C. M., Yao, J., Beeson, G. C., Coyle, R. C., Chen, X., Jia, J., Damon, B., Wilson, R., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0539-4 · Cited by 439
Majkut, S., Idema, T., Swift, J., Krieger, C., Liu, A., & Discher, D. E. (2013) · Current Biology · doi:10.1016/j.cub.2013.10.057 · Cited by 198
Metadata
- Authors
- Theret, D. P., Levesque, M. J., Sato, M., Nerem, R. M., & Wheeler, L. T.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1988-08-01
- Volume
- 110
- Issue
- 3
- Pages
- 190-199
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1974541126
- Cited by
- 382
- References
- 0
- FWCI
- 0.60
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The Application of a Homogeneous Half-Space Model in the Analysis of Endothelial Cell Micropipette Measurements. https://app.cochat.ai/papers/10.1115/1.3108430
- The paper
- Theret, D. P., Levesque, M. J., Sato, M., Nerem, R. M., & Wheeler, L. T. (1988). The Application of a Homogeneous Half-Space Model in the Analysis of Endothelial Cell Micropipette Measurements. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.3108430
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.