Errors Induced by Off-Axis Measurement of the Elastic Properties of Bone
The DOI matches its Crossref record.
Abstract
Misalignment between the axes of measurement and the material symmetry axes of bone causes error in anisotropic elastic property measurements. Measurements of Poisson’s ratio were strongly affected by misalignment errors. The mean errors in the measured Young’s moduli were 9.5 and 1.3 percent for cancellous and cortical bone, respectively, at a misalignment angle of 10 degrees. Mean errors of 1.1 and 5.0 percent in the measured shear moduli for cancellous and cortical bone, respectively, were found at a misalignment angle of 10 degrees. Although, cancellous bone tissue was assumed to have orthotropic elastic symmetry, the possibility of the greater symmetry of transverse isotropy was investigated. When the nine orthotropic elastic constants were forced to approximate the five transverse isotropic elastic constants, errors of over 60 percent were introduced. Therefore, it was concluded that cancellous bone is truly orthotropic and not transversely isotropic. A similar but less strong result for cortical bone tissue was obtained.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Trabecular bone modulus–density relationships depend on anatomic site
Morgan, E. F., Bayraktar, H. H., & Keaveny, T. M. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00071-x · Cited by 1,209
Biomechanics of Trabecular Bone
Keaveny, T. M., Morgan, E. F., Niebur, G. L., & Yeh, O. C. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.307 · Cited by 801
Three-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
The relationship between the structural and orthogonal compressive properties of trabecular bone
Goulet, R. W., Goldstein, S. A., Ciarelli, M. J., Kuhn, J. L., Brown, M. B., & Feldkamp, L. A. (1994) · Journal of Biomechanics · doi:10.1016/0021-9290(94)90014-0 · Cited by 741
Dependence of yield strain of human trabecular bone on anatomic site
Morgan, E. F., & Keaveny, T. M. (2001) · Journal of Biomechanics · doi:10.1016/s0021-9290(01)00011-2 · Cited by 705
Mathematical relationships between bone density and mechanical properties: A literature review
Helgason, B., Perilli, E., Schileo, E., Taddei, F., Brynjólfsson, S., & Viceconti, M. (2008) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2007.08.024 · Cited by 589
Three quantitative ultrasound parameters reflect bone structure
Gluer, C. C., Wu, C. Y., Jergas, M., Goldstein, S. A., & Genant, H. K. (1994) · Calcified Tissue International · doi:10.1007/bf00310168 · Cited by 424
The fabric dependence of the orthotropic elastic constants of cancellous bone
Turner, C. H., Cowin, S. C., Rho, J. Y., Ashman, R. B., & Rice, J. C. (1990) · Journal of Biomechanics · doi:10.1016/0021-9290(90)90048-8 · Cited by 346
Self-citationA 20-Year Perspective on the Mechanical Properties of Trabecular Bone
Keaveny, T. M., & Hayes, W. C. (1993) · Journal of Biomechanical Engineering · doi:10.1115/1.2895536 · Cited by 318
Variations in cortical material properties throughout the human dentate mandible
Schwartz‐Dabney, C. L., & Dechow, P. C. (2003) · American Journal of Physical Anthropology · doi:10.1002/ajpa.10121 · Cited by 314
A fabric-dependent fracture criterion for bone
Pietruszczak, S., Inglis, D., & Pande, G. N. (1999) · Journal of Biomechanics · doi:10.1016/s0021-9290(99)00096-2 · Cited by 51
Metadata
- Authors
- Turner, C. H., & Cowin, S. C.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1988-08-01
- Volume
- 110
- Issue
- 3
- Pages
- 213-215
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2110875241
- Cited by
- 56
- References
- 0
- FWCI
- 1.39
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.