The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Relationship Between Hypertension, Hypertrophy, and Opening Angle of Zero-Stress State of Arteries Following Aortic Constriction
Abstract
Examination of changes occurring in the zero-stress state of an organ provides a way to study cellular growth in the organ due to change of physical stresses. The zero-stress state of the aorta is not a tube. It is a sector with an opening angle that varies with the location on the aorta and changes with cellular remodeling. Blood vessel remodeling can be induced by imposing a constriction on the abdominal aorta by a metal clip (aortic banding), which causes an increase of blood pressure, hypertrophy of the aortic wall, and large change of opening angle. The correlation of the opening angle with the blood vessel wall thickness and blood pressure changes in rat’s aorta due to aortic banding is presented in this report. The opening angle changes daily following the aortic banding. Blood pressure rises in vessels of the upper body, but that in the lower body decreases at first and then rises to an asymptotic value. Blood vessel wall thickness increases in rough proportion to blood pressure. Vessel diameter changes also. But the most dramatic is the course of change of the zero-stress state. Typically, the time to reach 50 percent of asymptotic hypertrophy of blood vessel wall thickness is about 3–5 days. The corresponding time for blood pressure is about 7 days. The opening angle of the zero-stress state, however, increases rapidly at first, reaches a peak in about 2 to 4 days, then decreases gradually to a reduced asymptote. The exact values of the time constants depend on the location along the aortic tree. In general, the course of change of residual strain is very different from those of the blood pressure and the blood vessel wall thickness.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The variation in isometric tension with sarcomere length in vertebrate muscle fibres
Gordon, A. M., Huxley, A. F., & Julian, F. J. (1966) · The Journal of Physiology · doi:10.1113/jphysiol.1966.sp007909 · Cited by 3,152
Cited by
Finite element modeling of blood flow in arteries
Taylor, C. A., Hughes, T. J. R., & Zarins, C. K. (1998) · Computer Methods in Applied Mechanics and Engineering · doi:10.1016/s0045-7825(98)80008-x · Cited by 726
What are the residual stresses doing in our blood vessels?
Fung, Y. C. (1991) · Annals of Biomedical Engineering · doi:10.1007/bf02584301 · Cited by 362
Self-citationStress-Modulated Growth, Residual Stress, and Vascular Heterogeneity
Taber, L. A., & Humphrey, J. D. (2001) · Journal of Biomechanical Engineering · doi:10.1115/1.1412451 · Cited by 309
E XPERIMENTAL AND C OMPUTATIONAL M ETHODS IN C ARDIOVASCULAR F LUID M ECHANICS
Taylor, C. A., & Draney, M. T. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.121944 · Cited by 285
Metadata
- Authors
- Liu, S. Q., & Fung, Y. C.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 1989-11-01
- Volume
- 111
- Issue
- 4
- Pages
- 325-335
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W1999145834
- Cited by
- 203
- References
- 1
- FWCI
- 2.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Relationship Between Hypertension, Hypertrophy, and Opening Angle of Zero-Stress State of Arteries Following Aortic Constriction. https://app.cochat.ai/papers/10.1115/1.3168386
- The paper
- Liu, S. Q., & Fung, Y. C. (1989). Relationship Between Hypertension, Hypertrophy, and Opening Angle of Zero-Stress State of Arteries Following Aortic Constriction. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.3168386
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.