The DOI matches its Crossref record.
Combined Heat Transfer and Fluid Dynamic Measurements Downstream of a Backward-Facing Step
Abstract
Combined heat transfer and fluid dynamic measurements in a separated and reattaching boundary layer, with emphasis on the near-wall region, are presented. A constant heat-flux surface behind a single-sided sudden expansion is used to obtain Stanton number profiles as a function of Reynolds number and boundary-layer thickness at separation. Fluctuating skin-friction and temperature profiles demonstrate the importance of the near-wall region in controlling the heat transfer rate. The fluctuating skin friction controls the heat transfer rate near reattachment, while the conventional Reynolds analogy applies in the redeveloping boundary layer beginning two or three step heights downstream of reattachment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
DeJong, N. C., Zhang, L. W., Jacobi, A. M., Balachandar, S., & Tafti, D. K. (1998) · Journal of Heat Transfer · doi:10.1115/1.2824338 · Cited by 56
Metadata
- Authors
- Vogel, J. C., & Eaton, J. K.
- Venue
- Journal of Heat Transfer
- Publisher
- ASME International
- Published
- 1985-11-01
- Volume
- 107
- Issue
- 4
- Pages
- 922-929
- ISSN
- 0022-1481 (ISSN-L)
- 1528-8943
- OpenAlex
- W2089813247
- Cited by
- 391
- References
- 0
- FWCI
- 3.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Combined Heat Transfer and Fluid Dynamic Measurements Downstream of a Backward-Facing Step. https://app.cochat.ai/papers/10.1115/1.3247522
- The paper
- Vogel, J. C., & Eaton, J. K. (1985). Combined Heat Transfer and Fluid Dynamic Measurements Downstream of a Backward-Facing Step. Journal of Heat Transfer. https://doi.org/10.1115/1.3247522
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.