The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Multiscale Design and Multiobjective Optimization of Orthopedic Hip Implants with Functionally Graded Cellular Material
Open accessAbstract
Revision surgeries of total hip arthroplasty are often caused by a deficient structural compatibility of the implant. Two main culprits, among others, are bone-implant interface instability and bone resorption. To address these issues, in this paper we propose a novel type of implant, which, in contrast to current hip replacement implants made of either a fully solid or a foam material, consists of a lattice microstructure with nonhomogeneous distribution of material properties. A methodology based on multiscale mechanics and design optimization is introduced to synthesize a graded cellular implant that can minimize concurrently bone resorption and implant interface failure. The procedure is applied to the design of a 2D left implanted femur with optimized gradients of relative density. To assess the manufacturability of the graded cellular microstructure, a proof-of-concept is fabricated by using rapid prototyping. The results from the analysis are used to compare the optimized cellular implant with a fully dense titanium implant and a homogeneous foam implant with a relative density of 50%. The bone resorption and the maximum value of interface stress of the cellular implant are found to be over 70% and 50% less than the titanium implant while being 53% and 65% less than the foam implant.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast and elitist multiobjective genetic algorithm: NSGA-II
Deb, K., Pratap, A., Agarwal, S., & Meyarivan, T. (2002) · IEEE Transactions on Evolutionary Computation · doi:10.1109/4235.996017 · Cited by 50,053
Cited by
Additive manufacturing (3D printing): A review of materials, methods, applications and challenges
Ngo, T. D., Kashani, A., Imbalzano, G., Nguyen, K. T. Q., & Hui, D. (2018) · Composites Part B: Engineering · doi:10.1016/j.compositesb.2018.02.012 · Cited by 8,431
Current and future trends in topology optimization for additive manufacturing
Liu, J., Gaynor, A. T., Chen, S., Kang, Z., Suresh, K., Takezawa, A., Li, L., Kato, J., Tang, J., Wang, C. C. L., et al. (2018) · Structural and Multidisciplinary Optimization · doi:10.1007/s00158-018-1994-3 · Cited by 870
Properties and applications of additively manufactured metallic cellular materials: A review
du Plessis, A., Razavi, N., Benedetti, M., Murchio, S., Leary, M., Watson, M., Bhate, D., & Berto, F. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100918 · Cited by 623
Arabnejad, S., Burnett Johnston, R., Pura, J. A., Singh, B., Tanzer, M., & Pasini, D. (2016) · Acta Biomaterialia · doi:10.1016/j.actbio.2015.10.048 · Cited by 578
Self-citationLiu, L., Kamm, P., García-Moreno, F., Banhart, J., & Pasini, D. (2017) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2017.07.003 · Cited by 513
Self-citation
Metadata
- Authors
- Arabnejad Khanoki, S., & Pasini, D.
- Venue
- Journal of Biomechanical Engineering
- Publisher
- ASME International
- Published
- 2012-03-01
- Volume
- 134
- Issue
- 3
- Pages
- 031004-031004
- ISSN
- 0148-0731 (ISSN-L)
- 1528-8951
- OpenAlex
- W2089307546
- Cited by
- 192
- References
- 1
- FWCI
- 8.82
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Multiscale Design and Multiobjective Optimization of Orthopedic Hip Implants with Functionally Graded Cellular Material. https://app.cochat.ai/papers/10.1115/1.4006115
- The paper
- Arabnejad Khanoki, S., & Pasini, D. (2012). Multiscale Design and Multiobjective Optimization of Orthopedic Hip Implants with Functionally Graded Cellular Material. Journal of Biomechanical Engineering. https://doi.org/10.1115/1.4006115
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.