The DOI matches its Crossref record.
Experimental and Theoretical Study of Transverse Vibration of a Tube Containing Flowing Fluid
Abstract
The free transverse vibrations for the fundamental mode of a single-span tube containing a flowing fluid are investigated analytically and experimentally. An approximate solution of the differential equation of motion is made with an infinite power series. Care must be taken in evaluating the large-order determinant that appears so that erroneous results may be prevented. The solution indicates a slight decrease in frequency and no decaying vibration with an increase in flow rate that can be attributed to the flowing fluid for simply supported, fixed, and fixed-simple ends. For fixed-free ends a decaying vibration due to the flowing fluid is indicated and a slight frequency decrease. The experimental results agree reasonably well with these solutions, although the frequency decrease is within the experimental error. The theory neglects internal damping of the tube and “support” damping. The latter appears significant in magnitude and is evaluated for the constructions used. This paper shows the reason for the incorrect conclusions of previous paper and gives experimental results that tend to verify the analytical results presented here and those in another previous paper by a different procedure.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The Coriolis force generated when the fluid is transported at a high speed in a pipe may cause the pipe to lose its stability.
“the Coriolis force generated when the fluid is transported at a high speed in a pipe may cause the pipe to lose its stability [97][98] .”
From Vibration control of fluid-conveying pipes: a state-of-the-art review (2023) · cites this paper as [98]
The Coriolis force caused by the medium flow velocity may dampen the vibration of a cantilever pipe, but not for simply-supported or fixed fluid-conveying pipes at both ends.
“However, the Coriolis force caused by the medium flow velocity may dampen the vibration of a cantilever pipe, but not for simply-supported or fixed fluid-conveying pipes at both ends [98] .”
From Vibration control of fluid-conveying pipes: a state-of-the-art review (2023) · cites this paper as [98]
Citations
Cited by
Sorted by citations
Vibration control of fluid-conveying pipes: a state-of-the-art review
Ding, H., & Ji, J. C. (2023) · Applied Mathematics and Mechanics · doi:10.1007/s10483-023-3023-9 · Cited by 132
Metadata
- Authors
- Long, R. H.
- Affiliations
- University of Maryland, College Park (US)
- Corresponding author
- Long, R. H.
- Venue
- Journal of Applied Mechanics
- Publisher
- ASME International
- Published
- 1955-03-01
- Volume
- 22
- Issue
- 1
- Pages
- 65-68
- ISSN
- 0021-8936 (ISSN-L)
- 1528-9036
- OpenAlex
- W3172448753
- Cited by
- 72
- References
- 0
- Citations by year
- 2025: 3 · 2024: 1 · 2023: 7 · 2022: 4 · 2021: 4 · 2020: 4 · 2019: 2 · 2018: 2 · 2017: 5 · 2016: 3 · 2015: 3 · 2014: 1 · 2013: 1
- FWCI
- 2.53
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Applied Mechanics (publishedVersion)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Vibration and Dynamic Analysis
- Physical Sciences › Engineering › Computational Mechanics › Fluid Dynamics and Vibration Analysis
- Physical Sciences › Engineering › Computational Mechanics › Fluid dynamics and aerodynamics studies
- Keywords
- transverse vibration, fluid-filled tubes, free vibration, flow-induced vibration, natural frequencies, support damping, simply supported ends
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review