On the Automatic Control of Generalized Passive Systems

Chien, Kun Li, Hrones, J. A., Reswick, J. B.·1952·Journal of Fluids Engineering

Abstract

The dynamic behavior of a multiple-capacity passive system is compared to that of a single-capacity system of appropriate “time constant with a finite time delay.” Such a comparison indicates that the latter system reproduces the dynamic behavior of the multiple-capacity system with sufficient accuracy for most engineering purposes. This fact makes it possible to characterize such systems by a single parameter, the ratio of the time constant (L) of the single-capacity system to the delay (D). Values of the control constants for various degrees of stability are plotted against this ratio (L/D) for proportional, proportional-plus-integral, proportional-plus-integral-plus-derivative type regulators. An electronic analog computer was used in obtaining the data.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1115/1.4015724

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 496

Metadata

Authors
Chien, K. L., Hrones, J. A., & Reswick, J. B.
Venue
Journal of Fluids Engineering
Published
1952-02-01
Volume
74
Issue
2
Pages
175-183
ISSN
0097-6822 (ISSN-L)
OpenAlex
W2979268364
Cited by
496
References
0
FWCI
0.00
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: On the Automatic Control of Generalized Passive Systems. https://app.cochat.ai/papers/10.1115/1.4015724
The paper
Chien, K. L., Hrones, J. A., & Reswick, J. B. (1952). On the Automatic Control of Generalized Passive Systems. Journal of Fluids Engineering. https://doi.org/10.1115/1.4015724

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.