The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Recent Advances in High-Flux, Two-Phase Thermal Management
Open accessAbstract
Recent developments in applications such as computer data centers, electric vehicle power electronics, avionics, radars, and lasers have led to alarming increases in heat dissipation rate, which now far exceeds the capability of air cooling schemes and even the most aggressive single-phase liquid cooling schemes. This trend is responsible for a recent transition to two-phase cooling, which capitalizes upon the coolant's latent heat rather than sensible heat alone to achieve several order-of-magnitude increases in heat transfer coefficient. Three two-phase cooling configurations have surfaced as best contenders for the most demanding applications: mini/microchannel, jet, and spray. This study will explore the implementation of these configurations into practical cooling packages, assess available predictive tools, and identify future research needs for each. It is shown that the design and performance assessment of high-flux, two-phase cooling systems are highly dependent on empirical or semiempirical predictive tools and, to a far lesser extent, theoretical mechanistic models. A major challenge in using such tools is the lack of databases for coolants with drastically different thermophysical properties, and which cover broad ranges of such important parameters as flow passage size, mass velocity, quality, and pressure. Recommendations are therefore made for future research to correct any critical knowledge gaps, including the need for robust computer algorithms. Also discussed is a new class of “hybrid” cooling schemes that capitalize upon the merits of multiple cooling configurations. It is shown that these hybrid schemes not only surpass the basic cooling configurations in heat dissipation rate, but they also provide better surface temperature uniformity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fundamentals of heat and mass transfer
Hewitt, G. F. (2008) · Begellhouse eBooks · Cited by 12,932
Proposed Correlation of Data for Isothermal Two-Phase, Two-Component Flow in Pipes
Lockhart, R. W. (1949) · Chemical engineering progress · Cited by 2,727
(1978) · Cited by 1,056
Lee, J., & Mudawar, I. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.09.019 · Cited by 550
Self-citationHigh flux boiling in low flow rate, low pressure drop mini-channel and micro-channel heat sinks
Bowers, M. B., & Mudawar, I. (1994) · International Journal of Heat and Mass Transfer · doi:10.1016/0017-9310(94)90103-1 · Cited by 483
Self-citationTwo-Phase Microchannel Heat Sinks: Theory, Applications, and Limitations
Mudawar, I. (2011) · Journal of Electronic Packaging · doi:10.1115/1.4005300 · Cited by 347
Self-citationLee, J., & Mudawar, I. (2004) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2004.09.018 · Cited by 300
Self-citationA Review of Heat Transfer Issues in Hydrogen Storage Technologies
Zhang, J., Fisher, T. S., Ramachandran, P. V., Gore, J. P., & Mudawar, I. (2005) · Journal of Heat Transfer · doi:10.1115/1.2098875 · Cited by 201
Self-citationLee, J., & Mudawar, I. (2008) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2008.02.013 · Cited by 124
Self-citationKim, S. M., & Mudawar, I. (2012) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2012.02.061 · Cited by 60
Self-citationNacke, R. A., Northcutt, B., & Mudawar, I. (2010) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2010.10.028 · Cited by 46
Self-citation
Cited by
Review of spray cooling – Part 1: Single-phase and nucleate boiling regimes, and critical heat flux
Liang, G., & Mudawar, I. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.06.029 · Cited by 609
Self-citation
Metadata
- Authors
- Mudawar, I.
- Venue
- Journal of Thermal Science and Engineering Applications
- Publisher
- ASME International
- Published
- 2013-05-17
- Volume
- 5
- Issue
- 2
- ISSN
- 1948-5085 (ISSN-L)
- 1948-5093
- OpenAlex
- W2112588978
- Cited by
- 296
- References
- 11
- FWCI
- 4.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.