Cited by 33Robotic Mechanisms and DynamicsDynamics and Control of Mechanical SystemsSoft Robotics and Applications

The DOI matches its Crossref record; 46 of the 47 references it cites were found in a registry or an index.

Higher-Order Analysis of Kinematic Singularities of Lower Pair Linkages and Serial Manipulators

Müller, Andreas·2018·Journal of Mechanisms and Robotics

Abstract

Kinematic singularities of linkages are configurations where the differential mobility changes. Constraint singularities are critical points of the constraint mapping defining the loop closure constraints. Configuration space (c-space) singularities are points where the c-space ceases to be a smooth manifold. These singularity types are not identical and can neither be distinguished nor identified by simply investigating the rank deficiency of the constraint Jacobian (linear dependence of joint screws). C-space singularities are reflected by the c-space geometry. In a previous work, a kinematic tangent cone was introduced as an approximation of the c-space, defined as the set of tangents to smooth curves in c-space. Identification of kinematic singularities amounts to analyze the local geometry of the set of critical points. As a computational means, a kinematic tangent cone to the set of critical points is introduced in terms of Jacobian minors. Closed form expressions for the derivatives of the minors in terms of Lie brackets of joint screws are presented. A computational method is introduced to determine a polynomial system defining the kinematic tangent cone. The paper complements the recently proposed mobility analysis using the tangent cone to the c-space. This allows for identifying c-space and kinematic singularities as long as the solution set of the constraints is a real variety. The introduced approach is directly applicable to the higher-order analysis of forward kinematic singularities of serial manipulators. This is briefly addressed in the paper.

Overview

Integrity signals

Registry

Crossref · 10.1115/1.4038528

Cites

46 of 46 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 47 references

Research works printed but not linked: 1

  1. 2002, Constraint Singularity as C-Space Singularities, 183

Cited by

Sorted by citations

See all 33

Metadata

Authors
Müller, A.
Affiliations
Johannes Kepler University of Linz (AT)
Corresponding author
Müller, Andreas
Venue
Journal of Mechanisms and Robotics
Published
2017-12-22
Volume
10
Issue
1
ISSN
  • 1942-4302 (ISSN-L)
  • 1942-4310
OpenAlex
W2770014303
Cited by
33
References
47
Citations by year
2026: 2 · 2025: 2 · 2024: 3 · 2023: 3 · 2022: 4 · 2021: 4 · 2020: 5 · 2019: 7 · 2018: 3
FWCI
2.58
Type
journal article
Language
en
Open access
closed
Locations
Journal of Mechanisms and Robotics (publishedVersion)
Topics
  • Physical Sciences › Engineering › Control and Systems Engineering › Robotic Mechanisms and Dynamics
  • Physical Sciences › Engineering › Control and Systems Engineering › Dynamics and Control of Mechanical Systems
  • Physical Sciences › Engineering › Biomedical Engineering › Soft Robotics and Applications
Keywords
kinematic singularities, serial manipulators, constraint singularities, forward kinematics, differential mobility

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Higher-Order Analysis of Kinematic Singularities of Lower Pair Linkages and Serial Manipulators. https://app.cochat.ai/papers/10.1115/1.4038528
The paper
Müller, A. (2018). Higher-Order Analysis of Kinematic Singularities of Lower Pair Linkages and Serial Manipulators. Journal of Mechanisms and Robotics. https://doi.org/10.1115/1.4038528