The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Hip Implant Design With Three-Dimensional Porous Architecture of Optimized Graded Density
Abstract
Even in a well-functioning total hip replacement, significant peri-implant bone resorption can occur secondary to stress shielding. Stress shielding is caused by an undesired mismatch of elastic modulus between the stiffer implant and the adjacent bone tissue. To address this problem, we present here a microarchitected hip implant that consists of a three-dimensional (3D) graded lattice material with properties that are mechanically biocompatible with those of the femoral bone. Asymptotic homogenization (AH) is used to numerically determine the mechanical and fatigue properties of the implant, and a gradient-free scheme of topology optimization is used to find the optimized relative density distribution of the porous implant under multiple constraints dictated by implant micromotion, pore size, porosity, and minimum manufacturable thickness of the cell elements. Obtained for a 38-year-old patient femur, bone resorption is assessed by the difference in strain energy between the implanted bone and the intact bone in the postoperative conditions. The numerical results suggest that bone loss for the optimized porous implant is only 42% of that of a fully solid implant, here taken as benchmark, and 79% of that of a porous implant with uniform density. The architected hip implant presented in this work shows clinical promise in reducing bone loss while preventing implant micromotion, thereby contributing to reduce the risk of periprosthetic fracture and the probability of revision surgery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A fast and elitist multiobjective genetic algorithm: NSGA-II
Deb, K., Pratap, A., Agarwal, S., & Meyarivan, T. (2002) · IEEE Transactions on Evolutionary Computation · doi:10.1109/4235.996017 · Cited by 50,053
Cited by
Properties and applications of additively manufactured metallic cellular materials: A review
du Plessis, A., Razavi, N., Benedetti, M., Murchio, S., Leary, M., Watson, M., Bhate, D., & Berto, F. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100918 · Cited by 623
Chen, L.-Y., Liang, S.-X., Liu, Y., & Zhang, L.-C. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100648 · Cited by 603
A review on integration of lightweight gradient lattice structures in additive manufacturing parts
Seharing, A., Azman, A. H., & Abdullah, S. (2020) · Advances in Mechanical Engineering · doi:10.1177/1687814020916951 · Cited by 270
Metadata
- Authors
- Wang, Y., Arabnejad, S., Tanzer, M., & Pasini, D.
- Venue
- Journal of Mechanical Design
- Publisher
- ASME International
- Published
- 2018-09-07
- Volume
- 140
- Issue
- 11
- ISSN
- 0161-8458 (ISSN-L)
- 1050-0472
- 1528-9001
- OpenAlex
- W2888618823
- Cited by
- 185
- References
- 1
- FWCI
- 12.15
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.