Absorbance measurement of polymers at extreme ultraviolet wavelength: Correlation between experimental and theoretical calculations
The DOI matches its Crossref record.
Abstract
Performance requirements for extreme UV (EUV) resists will require the development of polymer platforms. A challenge in designing photoresists for EUV wavelengths is the selection of molecular structures that have minimal absorbance. For example, elements that are commonly used in photoresists at other wavelengths, such as oxygen and fluorine, are highly absorbing at ∼13nm making them problematic for EUV applications. In order to provide a tool for EUV resist design, this article presents a study of the absorbance of common photoresist structures and compares it to theoretical estimates of resist absorbance based on composition and density. On this basis, several potential structures suitable for EUV resists are assessed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Absorption coefficient of metal-containing photoresists in the extreme ultraviolet
Fallica, R., Haitjema, J., Wu, L., Castellanos Ortega, S., Brouwer, A. M., & Ekinci, Y. (2018) · Journal of Micro/Nanopatterning Materials and Metrology · doi:10.1117/1.jmm.17.2.023505 · Cited by 105
Extreme ultraviolet photoemission of a tin-based photoresist
Zhang, Y., Haitjema, J., Castellanos, S., Lugier, O., Sadegh, N., Ovsyannikov, R., Giangrisostomi, E., Johansson, F. O. L., Berggren, E., Lindblad, A., et al. (2021) · Applied Physics Letters · doi:10.1063/5.0047269 · Cited by 35
“16 In order to estimate the photoabsorption and photo-emission cross sections of the elements, values from the Centre for X-ray Optics, Berkeley database 17 often reasonably reproduce experimental data, 18–21 especially for the higher photon energies.”
Key Challenges and Opportunities for Advanced Extreme Ultraviolet Lithography Photoresist Materials
Li, M., & Aqad, E. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202420962 · Cited by 33
Robinson, A. P. G., & Lawson, R. A. (2016) · Frontiers of Nanoscience · doi:10.1016/b978-0-08-100354-1.00013-2 · Cited by 4
Metadata
- Authors
- Kwark, Y.-J., Bravo-Vasquez, J. P., Chandhok, M., Cao, H., Deng, H., Gullikson, E., & Ober, C. K.
- Venue
- Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena
- Publisher
- American Vacuum Society
- Published
- 2006-06-30
- Volume
- 24
- Issue
- 4
- Pages
- 1822-1826
- ISSN
- 1071-1023 (ISSN-L)
- 1520-8567
- OpenAlex
- W2065783144
- Cited by
- 44
- References
- 0
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Absorbance measurement of polymers at extreme ultraviolet wavelength: Correlation between experimental and theoretical calculations. https://app.cochat.ai/papers/10.1116/1.2214708
- The paper
- Kwark, Y.-J., Bravo-Vasquez, J. P., Chandhok, M., Cao, H., Deng, H., Gullikson, E., & Ober, C. K. (2006). Absorbance measurement of polymers at extreme ultraviolet wavelength: Correlation between experimental and theoretical calculations. Journal of Vacuum Science & Technology B: Microelectronics and Nanometer Structures Processing, Measurement, and Phenomena. https://doi.org/10.1116/1.2214708
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.