The DOI matches its Crossref record.
Application of laser-induced breakdown spectroscopy to in situ analysis of liquid samples
Abstract
A realization of laser-induced breakdown spectroscopy for real-time, in situ and remote analysis of trace amounts in liquid samples is described, which is potentially applicable to the analysis of pollutants in water in harsh or difficult-to-reach environments. Most of the measurements were conducted using a fiber assembly that is capable of both delivering the laser light and collecting the light emitted from the micro plasma, up to about 30 m from the target area. Alternatively, a telescopic arrangement for line-of-sight measurements was employed, with a range of 3 to 5 m. For internal standardization and the generation of concentration calibration curves, reference lines of selected elements were used. In the majority of cases calibration against the matrix element hydrogen was employed using the H?, H?, and H? lines, but also spiking with selected reference species was utilized. In order to provide high reliability and repeatability in the analyses, we also measured plasma parameters such as electron density, plasma temperature, and line- shape functions, and determined their influence on the measurement results. Numerous elements, including a range of toxic heavy metals, have been measured over a wide range of concentrations (Al, Cr, Cu, Pb, Tc, U, and others). Limits of detection usually were in the range of a few parts per million; for several elements even lower concentrations could be measured.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Hahn, D. W., & Omenetto, N. (2012) · Applied Spectroscopy · doi:10.1366/11-06574 · Cited by 1,497
Hahn, D. W., & Omenetto, N. (2010) · Applied Spectroscopy · doi:10.1366/000370210793561691 · Cited by 1,068
Aragón, C., & Aguilera, J. A. (2008) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2008.05.010 · Cited by 636
Harmon, R. S., Russo, R. E., & Hark, R. R. (2013) · Spectrochimica Acta Part B: Atomic Spectroscopy · doi:10.1016/j.sab.2013.05.017 · Cited by 335
Algal Biomass Analysis by Laser-Based Analytical Techniques—A Review
Pořízka, P., Prochazková, P., Prochazka, D., Sládková, L., Novotný, J., Petrilak, M., Brada, M., Samek, O., Pilát, Z., Zemánek, P., et al. (2014) · Sensors · doi:10.3390/s140917725 · Cited by 61
Self-citation
Metadata
- Authors
- Beddows, D. C. S.
- Venue
- Optical Engineering
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2000-08-01
- Volume
- 39
- Issue
- 8
- Pages
- 2248
- ISSN
- 0091-3286 (ISSN-L)
- OpenAlex
- W2014830296
- Cited by
- 227
- References
- 0
- FWCI
- 15.84
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Application of laser-induced breakdown spectroscopy to in situ analysis of liquid samples. https://app.cochat.ai/papers/10.1117/1.1304855
- The paper
- Beddows, D. C. S. (2000). Application of laser-induced breakdown spectroscopy to in situ analysis of liquid samples. Optical Engineering. https://doi.org/10.1117/1.1304855
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.