The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Automated single-cell sorting system based on optical trapping
Open accessAbstract
We provide a basis for automated single-cell sorting based on optical trapping and manipulation using human peripheral blood as a model system. A counterpropagating dual-beam optical-trapping configuration is shown theoretically and experimentally to be preferred due to a greater ability to manipulate cells in three dimensions. Theoretical analysis performed by simulating the propagation of rays through the region containing an erythrocyte (red blood cell) divided into numerous elements confirms experimental results showing that a trapped erythrocyte orients with its longest axis in the direction of propagation of the beam. The single-cell sorting system includes an image-processing system using thresholding, background subtraction, and edge-enhancement algorithms, which allows for the identification of single cells. Erythrocytes have been identified and manipulated into designated volumes using the automated dual-beam trap. Potential applications of automated single-cell sorting, including the incorporation of molecular biology techniques, are discussed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Direct observation of kinesin stepping by optical trapping interferometry
Svoboda, K., Schmidt, C. F., Schnapp, B. J., & Block, S. M. (1993) · Nature · doi:10.1038/365721a0 · Cited by 1,910
Cited by
Optical tweezers for single cells
Zhang, H., & Liu, K.-K. (2008) · Journal of The Royal Society Interface · doi:10.1098/rsif.2008.0052 · Cited by 768
Laser‐Induced Release of Encapsulated Materials inside Living Cells
Skirtach, A. G., Muñoz Javier, A., Kreft, O., Köhler, K., Piera Alberola, A., Möhwald, H., Parak, W. J., & Sukhorukov, G. B. (2006) · Angewandte Chemie International Edition · doi:10.1002/anie.200504599 · Cited by 492
Self-citationLaser‐Induced Release of Encapsulated Materials inside Living Cells
Skirtach, A. G., Muñoz Javier, A., Kreft, O., Köhler, K., Piera Alberola, A., Möhwald, H., Parak, W. J., & Sukhorukov, G. B. (2006) · Angewandte Chemie · doi:10.1002/ange.200504599 · Cited by 455
Self-citationTong, L., Miljković, V. D., & Käll, M. (2010) · Nano Letters · doi:10.1021/nl9034434 · Cited by 281
Airborne chemistry: acoustic levitation in chemical analysis
Santesson, S., & Nilsson, S. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-003-2403-2 · Cited by 262
Metadata
- Authors
- Grover, S. C., Skirtach, A. G., Gauthier, R. C., & Grover, C. P.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2001
- Volume
- 6
- Issue
- 1
- Pages
- 14
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2080236079
- Cited by
- 160
- References
- 1
- FWCI
- 4.01
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Automated single-cell sorting system based on optical trapping. https://app.cochat.ai/papers/10.1117/1.1333676
- The paper
- Grover, S. C., Skirtach, A. G., Gauthier, R. C., & Grover, C. P. (2001). Automated single-cell sorting system based on optical trapping. Journal of Biomedical Optics. https://doi.org/10.1117/1.1333676
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.