The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Second-harmonic imaging microscopy of living cells
Open accessAbstract
Second harmonic generation (SHG) has been developed in our laboratories as a high-resolution nonlinear optical imaging microscopy for cellular membranes and intact tissues. SHG shares many of the advantageous features for microscopy of another more established nonlinear optical technique: two-photon excited fluorescence (TPEF). Both are capable of optical sectioning to produce three-dimensional images of thick specimens and both result in less photodamage to living tissue than confocal microscopy. SHG is complementary to TPEF in that it uses a different contrast mechanism and is most easily detected in the transmitted light optical path. It can be used to image membrane probes with high membrane specificity and displays extraordinary sensitivity in reporting membrane potential; it also has the ability to image highly ordered structural proteins without any exogenous labels.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Kleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Cited by
Nanochemistry and Nanomedicine for Nanoparticle-based Diagnostics and Therapy
Chen, G., Roy, I., Yang, C., & Prasad, P. N. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00148 · Cited by 1,499
Campagnola, P. J., & Loew, L. M. (2003) · Nature Biotechnology · doi:10.1038/nbt894 · Cited by 1,326
Self-citationZoumi, A., Yeh, A., & Tromberg, B. J. (2002) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.172368799 · Cited by 870
3-Dimensional imaging of collagen using second harmonic generation
Cox, G., Kable, E., Jones, A., Fraser, I., Manconi, F., & Gorrell, M. D. (2003) · Journal of Structural Biology · doi:10.1016/s1047-8477(02)00576-2 · Cited by 430
Polarization-Modulated Second Harmonic Generation in Collagen
Stoller, P., Reiser, K. M., Celliers, P. M., & Rubenchik, A. M. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75673-7 · Cited by 400
Metadata
- Authors
- Campagnola, P. J., Clark, H. A., Mohler, W. A., Lewis, A., & Loew, L. M.
- Venue
- Journal of Biomedical Optics
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2001
- Volume
- 6
- Issue
- 3
- Pages
- 277
- ISSN
- 1083-3668 (ISSN-L)
- OpenAlex
- W2120437765
- Cited by
- 244
- References
- 1
- FWCI
- 8.94
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Second-harmonic imaging microscopy of living cells. https://app.cochat.ai/papers/10.1117/1.1383294
- The paper
- Campagnola, P. J., Clark, H. A., Mohler, W. A., Lewis, A., & Loew, L. M. (2001). Second-harmonic imaging microscopy of living cells. Journal of Biomedical Optics. https://doi.org/10.1117/1.1383294
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.