The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Subpixel displacement and deformation gradient measurement using digital image/speckle correlation (DISC)
Abstract
Experimental solid mechanics relies heavily on surface displacement and deformation gradient measurements. Digital image/ speckle correlation (DISC) uses digital image processing to resolve displacement and deformation gradient fields. The practical implementation of DISC involves important challenges such as computation complexity and the discrepancy of the sensitivities and accuracies claimed in previous studies. We develop an iterative, spatial-gradient based algorithm, which uses only first-order spatial derivatives of the images before and after deformation. Simulated images are then used to verify this algorithm, as well as to study the impact of speckle size on the accuracy. Based on these simulations, the sensitivity of DISC to displacement and deformation gradient, as well as an optimal speckle size for optimal accuracy, is recommended. The algorithm is then calibrated using rigid body translation and rotation, and an application of DISC to thermomechanical diagnostics of electronic packaging is also presented.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Digital Imaging Techniques In Experimental Stress Analysis
Peters, W. H., & Ranson, W. F. (1982) · Optical Engineering · doi:10.1117/12.7972925 · Cited by 1,884
Digital image correlation using Newton-Raphson method of partial differential correction
Bruck, H. A., McNeill, S. R., Sutton, M. A., & Peters, W. H. (1989) · Experimental Mechanics · doi:10.1007/bf02321405 · Cited by 1,456
Submicron deformation field measurements: Part 2. Improved digital image correlation
Vendroux, G., & Knauss, W. G. (1998) · Experimental Mechanics · doi:10.1007/bf02321649 · Cited by 516
Statistics of subpixel registration algorithms based on spatiotemporal gradients or block matching
Davis, C. Q., & Freeman, D. M. (1998) · Optical Engineering · doi:10.1117/1.601966 · Cited by 142
Three-dimensional particle velocimetry
Hinsch, K. (1995) · Measurement Science and Technology · doi:10.1088/0957-0233/6/6/012 · Cited by 127
Particle image velocimetry—status and trends
Buchhave, P. (1992) · Experimental Thermal and Fluid Science · doi:10.1016/0894-1777(92)90016-x · Cited by 93
Cited by
Two-dimensional digital image correlation for in-plane displacement and strain measurement: a review
Pan, B., Qian, K., Xie, H., & Asundi, A. (2009) · Measurement Science and Technology · doi:10.1088/0957-0233/20/6/062001 · Cited by 3,166
Pan, B. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aac55b · Cited by 887
Pan, B. (2007) · Optical Engineering · doi:10.1117/1.2714926 · Cited by 313
A review of optical NDT technologies
Zhu, Y.-K., Tian, G.-Y., Lu, R.-S., & Zhang, H. (2011) · Sensors · doi:10.3390/s110807773 · Cited by 228
Metadata
- Authors
- Zhou, P.
- Venue
- Optical Engineering
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2001-08-01
- Volume
- 40
- Issue
- 8
- Pages
- 1613
- ISSN
- 0091-3286 (ISSN-L)
- OpenAlex
- W2045725879
- Cited by
- 425
- References
- 6
- FWCI
- 2.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Subpixel displacement and deformation gradient measurement using digital image/speckle correlation (DISC). https://app.cochat.ai/papers/10.1117/1.1387992
- The paper
- Zhou, P. (2001). Subpixel displacement and deformation gradient measurement using digital image/speckle correlation (DISC). Optical Engineering. https://doi.org/10.1117/1.1387992
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.