The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Review of 20 years of range sensor development
Abstract
We review 20 years of development in the field of 3-D laser imaging. An overview of 3-D digitizing techniques is presented with an emphasis on commercial techniques and systems currently available. It covers some of the most important methods that have been developed, both at the National Research Council of Canada (NRC) and elsewhere, with a focus on commercial systems that are considered good representations of the key technologies that have survived the test of years.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Overview of three-dimensional shape measurement using optical methods
Brown, G. M. (2000) · Optical Engineering · doi:10.1117/1.602438 · Cited by 1,327
A Perspective on Range Finding Techniques for Computer Vision
Jarvis, R. A. (1983) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1983.4767365 · Cited by 782
Active, optical range imaging sensors
Besl, P. J. (1988) · Machine Vision and Applications · doi:10.1007/bf01212277 · Cited by 559
Eye-safe digital 3-D sensing for space applications
Beraldin, J. ‐., Blais, F., Rioux, M., Cournoyer, L., Laurin, D. G., & MacLean, S. G. (2000) · Optical Engineering · doi:10.1117/1.602352 · Cited by 35
Self-citationA Very Compact Real Time 3-D Range Sensor For Mobile Robot Applications
Blais, F., Rioux, M., Domey, J., & Beraldin, J. ‐. (1989) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.949112 · Cited by 14
Self-citation
Cited by
Phase shifting algorithms for fringe projection profilometry: A review
Zuo, C., Feng, S., Huang, L., Tao, T., Yin, W., & Chen, Q. (2018) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2018.04.019 · Cited by 1,291
Image‐based 3D Modelling: A Review
Remondino, F., & El‐Hakim, S. (2006) · The Photogrammetric Record · doi:10.1111/j.1477-9730.2006.00383.x · Cited by 1,019
Titanium Dioxide Nanomaterials for Sensor Applications
Bai, J., & Zhou, B. (2014) · Chemical Reviews · doi:10.1021/cr400625j · Cited by 900
Deep learning in optical metrology: a review
Zuo, C., Qian, J., Feng, S., Yin, W., Li, Y., Fan, P., Han, J., Qian, K., & Chen, Q. (2022) · Light: Science & Applications · doi:10.1038/s41377-022-00714-x · Cited by 711
Lock-in Time-of-Flight (ToF) Cameras: A Survey
Foix, S., Alenya, G., & Torras, C. (2011) · IEEE Sensors Journal · doi:10.1109/jsen.2010.2101060 · Cited by 644
Metadata
- Authors
- Blais, F.
- Venue
- Journal of Electronic Imaging
- Publisher
- SPIE-Intl Soc Optical Eng
- Published
- 2004-01-01
- Volume
- 13
- Issue
- 1
- Pages
- 231
- ISSN
- 1017-9909 (ISSN-L)
- OpenAlex
- W3020867216
- Cited by
- 907
- References
- 5
- FWCI
- 42.43
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.